background image

    >  Before any operation ensures that the main power supply is turned OFF 
    >  All electrical connections must be made out of water 
    >  Do not handle with wet feet 
    >  Comply with the current standards regarding accident prevention 
    >  In this regard, the IEC 364-7-702 standards must be observed : WIRING IN 
 

BUILDINGS, SPECIAL WIRING, SWIMMING POOLS. 

    >  The persons in charge of the assembly of this product must have the qualification 
 

required for this kind of work 

    

>  Stop by the remote corresponds to a standby mode.  If stopping over 24 hours, it is   

        recommended to use the switch located upstream of the transformer

 

6. OPERATION 

The system offers 16 programs including 11 static colours and 5 automatic modes. 
The  control  is  made  manually  by  the  remote  controller  provided  and  also  short  cuts  of  the  current. 
Each  fast  cut  of  the  current  (less  than  2  seconds)  makes  change  the  programs.  After  leaving  the 
lamps OFF for over 10 seconds, switch ON restarts from the last program used. 
The use of the remote controller requires a positioning facia to the lamp at a maximum distance of 10 
meters, unfolded antenna. Metallic part closed to the lamp can cut the radio reception and the distance 
of use under 1 to 2 meters. 
At first use, the remote controller needs to be paired with the receiver installed in the projector.

 

 
>>> Pairing process : 

  

Install the battery in the remote controller and switch on the projector 

  

Press the buttons 

O

 & 

S

 together during 5 seconds 

  

Each lamp connected flash several times  to valid the pairing and keep a static colour 

Press several times the button 

C

 or 

P

 until obtaining the colour or the desired program. 

 

 
7. SAFETY WARNINGS 
 
 

 
 

 
 
 

 

 
 
 

 
8. GUARANTEE 

This  PAR56  LED  lamp  is  guaranteed  24  months  against  any  material  and/or  manufacture  defect 
(electronic components) from the date of delivery. (Keep the purchase invoice/receipt) 
The  lamp  is  not  guaranteed  against  problems  coming  from  external  shock,  electric  short-circuit  or 
excessive  screwing.  The  product  is  not  guaranteed  against  electrical  excessive  voltage  coming from 
the external power supply. (In this case, refer to the house insurance coverage) 
This  guarantee  is  conditioned  with  the  strict  respect  of  these  instructions  of  assembly  and 
maintenance. Under this guarantee, the only obligation falling on the manufacturer or distributor will be 
the  free  replacement  or  repair  of  the  product  or  the  element  found  defective  by  their  after  sale 
services.  All  the  other  expenses  will  be  the  responsibility  of  the  purchaser.  For  any  replacement  or 
repair, the product must be subjected to an inspection to the after-sales service of the manufacturer or 
distributor. 
The guarantee does not play in the event of apparent vice. 
The  defects  and  deteriorations  caused  by  the  fair  wear  and  tear,  the  defects  resulting  from  a  wrong 
assembly and/or employment, and the modifications of the product carried out without the written and 
preliminary assent of the manufacturer are all also excluded. 
 
 

9. ENVIRONMENTAL INFORMATION 

In accordance with the European Directive 2002/96/CE, concerning the electric and 
electronic component scrap (EEED), the consumer must turn over the used product to 
the collect points envisaged to this end. 

 
 
 
 
 
 
 

Summary of Contents for LEDINPOOL 502822

Page 1: ...TER PAR56 LED LAMP 502822 502839 INSTALLATION MAINTENANCE MANUAL RoHS REACH https wszystkodobasenow pl zarowka do basenu led rgb z pilotem ŻARÓWKA LED RGB Z PILOTEM DO LAMP BASENOWYCH INSTRUKCJA MONTAŻU I OBSŁUGI ...

Page 2: ...rew terminal Terminales que deben atornillarse Terminali da avvitare Schraubkontakte 2 Connecteurs Connectors Conectores Connettori Anschlussklemme 3 Câble d alimentation Power supply cable Cable de alimentación Cavo d alimentazione Kabelschuh ...

Page 3: ...power socket which feeds the installation lamp will have to possess a device of protection by residual current with a maximal intensity of 30mA This projector will be only connected to a 12V security transformer with double winding Another type of transformer is prohibited The power of this transformer will be always higher than the power of all projectors connected The manufacturer is not respons...

Page 4: ...lid the pairing and keep a static colour Press several times the button C or P until obtaining the colour or the desired program 7 SAFETY WARNINGS 8 GUARANTEE This PAR56 LED lamp is guaranteed 24 months against any material and or manufacture defect electronic components from the date of delivery Keep the purchase invoice receipt The lamp is not guaranteed against problems coming from external sho...

Page 5: ......

Page 6: ...er On Off mando a distancia On Off telecomando radio On Off Funkfernbedienung On Off telecomando rádio 12V 50 60HZ 12V 50 60HZ 12V 50 60HZ 12V 50 60HZ 12V 50 60HZ 12V 50 60HZ 180 510 lumens 10 full RGB 510 lumens 10 full RGB 510 lumens 10 full RGB 510 lumens 10 full RGB 510 lumens 10 full RGB 510 lumens 10 full RGB P max 16 0W 10 16 0W 10 16 0W 10 16 0W 10 16 0W 10 16 0W 10 IEE PF 0 75 0 75 0 75 0...

Reviews: