6.2. 

  

Close the release valve (

41

) by turning it clockwise until it is firmly closed.

6.3. 

  

Connect the air inlet fitting into the workshop air supply hose lock fitting, turn on the air valve (

40

) to let the pump work until serrated   

 

saddle (

5

) nears workpiece, then turn off the air valve. When air source is unavailable, pump the handle (

48

) until serrated saddle    

 

nears workpiece.

6.4. 

  

Align workpiece and ram to ensure centre-loading. Before applying any pressure to the workpiece, recheck the alignment with the ram  

 

and ensure that the workpiece and press tools are supported in such a way that they cannot flex.

 

‰

   WarninG!

 

do not

 apply off centre loads.

6.5. 

  

Turn on the air valve or pump the handle to apply load onto workpiece.

6.6. 

  

When work is done, turn off the air valve (or stop pumping handle), slowly and carefully remove load from workpiece by turning the    

 

release valve counter-clockwise in small increments.

6.7. 

  

once ram has fully retracted, remove workpiece from the press bed frame.

6.8. 

  

disconnect the air inlet fitting from the air source. 

 note: 

Always keep the piston retracted after use to avoid ram corrosion.

7.  Maintenance

  

note:

 maintenance and repair must only be carried out by qualified person. Contact your Sealey stockist for details.

7.1.    

When the press is not in use, the hydraulic unit ram must be fully retracted to minimise corrosion. Remove the handle to inactivate the 

 press.

7.2.    

lubricate all moving parts at regular intervals.

7.3.    

Always keep the press clean, dry, and protected from harsh conditions.

7.4.    

Should you need to replace the oil, ensure the hydraulic unit ram is fully retracted. An excess of oil will render the press inoperative.

7.5.    

Use only appropriate Sealey hydraulic jack oil (Sealey Part number: HJo500mlS/HJo5lS). 

do not

 use brake fluid. 

7.6. 

  

Purge the system to remove any air (see 5.4).

7.7.    

If press efficiency begins to drop, purge the system to eliminate any air from the hydraulic system (see 5.4).

7.8.    

Check your model parts information for spares. 

Original Language Version

© Jack Sealey limited

enVironMent protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.