5. OPERATION

6. MAINTAINANCE

5.1

Dual Voltage Models XRC55 & XRC90.

Before operating the 

unit ensure that the correct voltage has been selected.

5.2

Continuous operation in manual mode.

5.2.1

Connect the unit to the mains power supply.

5.2.2

Switch the unit on by moving the on/off switch to the ‘I’ position at

which point the switch should illuminate. After a few minutes the 

green LED on the control panel will illuminate indicating that the 

compressor has started. In this mode the unit will dry the air 

continuously until the unit is switched off again.

5.2.3

To switch the unit off move the on/off switch to the ‘O’ position.

5.3

Automatic operation using a remote hygrostat. (Optional)

5.3.1

Connect the unit to the mains power supply.

5.3.2

Connect the hygrostat lead to the jack socket on the units control

panel. Switch the unit on. After a few minutes the green LED will 

illuminate and the compressor will start to rotate. Set the desired 

level of humidity on the hygrostat. If the general humidity is 

higher than the preset value the unit will start to operate. When 

the humidity has reached the preset value the compressor will be

switched off automatically but the fan will continue to operate. 

When the air humidity increases above the preset value the 

compressor will cut in again. This automatic cycling will continue 

until the unit is switched off. 

5.4

Electronic control. 

5.4.1

Each dehumidifier is equiped with an electronic control 

unit with related LED display panel which can be seen on the 

rear of the dehumidifier. The functions of the LEDs are as 

follows, (see fig.6).

5.4.2

Œ

ORANGE LED. The room temperature is too low or the unit 

is in defrost mode.

5.4.3



RED LED. The room temperature is too high or a reduction 

of air flow has occurred. Check filter and remove obstructions to

air flow if required. Check that the fan is rotating.

5.4.4

Ž

YELLOW LED. The water tank is full. Empty tank or check pump.

5.4.5



GREEN LED. The compressor is running.

6.1

Unplug the unit from the power supply before carrying out any maintenance or service.

6.2

Cleaning the filter.

To maintain the efficiency of the unit wash the filter in luke warm water on a regular basis.

6.3

Cleaning the unit.

Clean the unit at least once a year. Remove air filter, remove front and rear panels to gain access to inner 

parts. Clean inner parts using compressed air paying particular attention to the condenser, evaporator and water drainage tray.

fig. 6

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof 

of which will be required for any claim. 

INFORMATION: 

Call us for a copy of our latest catalogue on 01284 757525 and leave your full name 

and address including your postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

Declaration of Conformity

We, the sole importer into the UK, declare that the products listed below are in conformity withthe following standards and directives.

The construction files for these products are held by the Manufacturer and may

be inspected, by a national authority, upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Tools.

Signed by Mark Sweetman

14th April 2003