Sealey WPW9355 Quick Start Manual Download Page 2

2.  INTRODUCTION

Manufactured from high impact stainless steel for added durability and corrosion resistance. Ideal for installing in traditional wells, clean water 

deposits, boreholes and garden irrigation systems. Nine stage pump enables high flow rates, high heads and ensures a stable performance.

3.  SPECIFICATION

Model No:

 .................................................................

WPW9355

 

Cut Out: ...........................................................................Manual                 

Outlet OD: ........................................................................ 38mm

Maximum Output: .............................................. 93ltr(20gal)/min

Maximum Head: ................................................................ 55mtr 

Number of Stages: ................................................................... 9 

Motor Power: ...................................................................1000W

Supply:................................................................................230V

Nett weight: ......................................................................11.9kg

4.  OPERATION

 

WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.

4.1. 

  

Start-up.

4.1.1.   

Use the rope supplied to lower into the water, make sure that the pump remains clear of any silt or debris at the bottom of the borehole  

 

or well etc. (Fig.2).

4.1.2.   

Maximum immersion depth is to 15m and minimum bore hole diameter is 300mm.

4.1.3.   

Use the red switch to turn the pump on and off.

5.  MAINTENANCE

 

WARNING! With the exceptions listed below, all pump and electrical cable service maintenance and repair must be  

 

 

undertaken by an authorised service agent only. Failure to observe this rule may be dangerous and will invalidate your warranty.

 

WARNING! Ensure that the pump is disconnected from the mains power supply before attempting any service or maintenance.

5.1. 

  

Cleaning the perforated end cap.

5.1.1.   

Unscrew the end cap anticlockwise.(Fig.3).

5.1.2.   

Rinse out with clean cold water.

Caution: Never use the pump without the filter in place as this could lead to damage to the pump.

fig. 2

fig. 3

fig. 1

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

WPW9355  Issue: 2 (HF) - 02/10/18