background image

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

important:

 no liability is accepted for incorrect use of this product.

WarrantY:

 Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

K

empson Way, Suffolk Business Park,

B

ury st. edmunds, suffolk.

i

P32 7AR

www.sealey.co.uk

[email protected]

01284 757500

01284 703534

Web

environmental protection 

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, 

taken to a recycling centre and disposed of in a manner which is compatible with the environment.

Weee regulations 

d

ispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic 

Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. 

contact your local solid waste authority for recycling information. 

7.2.5. 

  

store device in a frost-free room (at least 5 °c).

8.  troubleshooting

fault

cause

remedy

Pump does not work

no power supply

check power cable, plug, supply

motor overheat due to high liquid 

temperature

eliminate cause of overheating (max. liquid temperature is 35°c)

motor overheats due to blocked 

ventilation slots

eliminate cause of overheating

residual current device activated

reset

motor defective

contact dealer

delivery rate too slow

W

ater shortage

e

nsure sufficient water supply

not enough pressure

suction pipe not sealed

seal suction pipe, tighten screwed connections

delivery rate too slow

suction height too high

observe maximum suction height 8mtr.

suction height must be deducted from the conveyance height.

filter blocked or soiled

c

lean or replace filter

check valve blocked

clean or replace valve

W

ater leak between motor and pump, 

shaft sealing not sealed

contact dealer

Pump is blocked or defective

clean pump with clean water and remove the cause of the 

contamination

Air in the pump or suction pipe

fill pump case with water. 

f

or suction pipes with a check valve, fill the suction pipe with water

Pressure switch faulty

contact dealer

suction pipe sucked in on the ground shorten or fasten suction pipe

u

se filter screen with check valve

Pump does not switch off

cut out pressure set too high

contact dealer

Pressure side unsealed

WPB062S.V2| Issue 1 01/07/16

Original Language Version

© Jack sealey limited

Summary of Contents for WPB062S.V2

Page 1: ... electrician a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Pump must be...

Page 2: ...ing pools the pump must be set up so as to guard against overflowing and protect against falling in 4 5 The installation site must be well ventilated and protected from the effects of weather 4 6 When operating indoors you must ensure that there is a drain in the floor or a leak prevention mechanism 4 7 Before starting up check the suction hose to ensure that it is sealed Bubbles of air in the suc...

Page 3: ... certain circumstances result in too high a pressure 5 2 3 Plug in the mains plug 5 2 4 Open pressure line turn on water spigot or nozzle 5 2 5 Turn pump on at the On Off switch Check to be sure that water is coming out 5 2 6 If the motor does not start up or the pump does not build up any pressure or if similar faults occur turn the device off and try to remedy the error see Troubleshooting secti...

Page 4: ...se Remedy Pump does not work No power supply Check power cable plug supply Motor overheat due to high liquid temperature Eliminate cause of overheating max liquid temperature is 35 C Motor overheats due to blocked ventilation slots Eliminate cause of overheating Residual current device activated Reset Motor defective Contact dealer Delivery rate too slow Water shortage Ensure sufficient water supp...