The WFS/94.V2 must be unpacked and installed indoors. 

THIS UNIT IS NOT FOR USE OUTDOORS.

3.1.

This extractor may be used as a transportable free standing unit, or securely fixed to a level surface capable of supporting
the unit’s weight.

3.2.

Allow adequate surrounding space to assure the necessary ventilation.

3.3.

To fix the extraction hose (Fig 1 A.) undo the two clips ‘B’ and remove the front panel ‘C’. Remove the large plastic nut ‘A1’ from the 

hose connector. Pass the hose connector through the centre hole of panel ‘C’ and secure with large 

plastic nut ‘A1’.

3.

INSTALLATION

4.

OPERATING INSTRUCTIONS

5. MAINTENANCE

6. SPARE 

PARTS

5.1.

General

5.1.1.

Ensure the mains switch is unplugged before attempting repair or maintenance.

5.1.2.

Keep the unit clean, wipe with a damp cloth, do not use abrasive materials.

5.1.3.

Regularly check extraction hose and head to ensure they are clean and not worn, or damaged.

5.2.

Filter Cartridge.

The durability of the filter cartridge depends on the way the cleaner is used and the quantity 
of collected impurities. Periodically check the suction capacity of the unit and replace the 
cartridge if there is a decrease in the unit’s performance.

5.2.1.

For easy access to the filter compartment stand the unit upright on a clean protected surface.

5.2.2.

To change the filter undo the side clasps which hold the filter cover (fig 1 B).

5.2.3.

Undo the two wing nuts (fig 2 D), remove the cover plate “E” and soiled filter “F”. Use an air line
to clean the filter compartment, fit the new filter and cover plate.

5.2.4.

Firmly re-tighten the wing nuts “D”, position the cover plate (fig C) and lock clasps “B”
(the locking clasps may be adjusted by turning the locking head).

5.2.5.

To replace the “After Filter” (at the other end of the unit), stand the unit correctly, undo hand bolts
(Fig 3 G), remove grid “H”, replace the soiled “After filter” “I” and re-fit grid “H”. 

Note:

The filter cartridges are disposable and must be placed in a sealed airtight container 
and disposed of according to local regulations relating to the type of waste contained in the filter. 

4.1.

Ensure the unit is switched off and is unplugged from the mains power supply.

4.2.

Check the filter compartment end panel (Fig 1 C.). and ensure that clips “B” are securely locked.

4.3.

Ensure the surrounding area will provide adequate ventilation, and that there are no obstructions
in front of the air outlet.

4.4.

Place the extraction cone (by use of attached magnet) as close as possible to the area from 
which fumes will be emitted.

4.5.

To avoid possibility of accidents, ensure the suction hose is laid safely so that it will not obstruction pedestrian, or vehicle pathways.

4.6.

Plug into the mains power, and switch the extraction motor switch “X”, on.  (The switch will light).

4.7.

Continue to run the extraction unit for a short time after welding is completed. 

4.8.

When task is complete, switch the motor off and disconnect from the mains, clean and store the unit in a safe, dry, childproof area.     

Fig 1

Fig 2

Fig 3

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed below is in conformity with the following standards and directives

The construction file for this product is held by the Manufacturer and may be inspected on
request by contacting Jack Sealey Ltd

For Jack Sealey Ltd.  Sole importer into the UK of Sealey Power Products

Signed by Mark Sweetman

Date 10th November 2006

Welding Fume Extractor Model No: WFS/94.V2

89/392/EC Machinery Directive

73/23/EEC Low Voltage Directive

89/336/EEC EMC Directive

93/68/EEC Marking Directive 

WFS/94.V2 (1) 10/11/06

01284 757500

01284 703534

[email protected]

Sole UK Distributor
Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.

ITEM

PART NO

DESCRIPTION

1

WFS94X/01

FILTER, CARTRIDGE

2

WFS94X/02

MOTOR, 230V 

3

WFS94X/03

FILTER, CARBON ACTIVATED

4

WFS94X/04

5 METRES OF FLEXIBLE HOSE

5

WFS94X/05

CONNECTION, PIPE

6

WFS94X/06

HANDLE (SO)

7

WFS94X/07

SWITCH

8

WFS94X/08

LAMP

9

WFS94X/09

CONNECTION, CABLE

10

WFS94X/10

MAGNET "RED PART"

11

WFS94X/11

END CONE "BLACK PART"

ISSUE NO.1

ISSUE DATE 13/11/06