background image

MINI DIGITAL THERMOMETER

MODEL NO: 

VS906

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

‰

   WARNING! 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

 

9

   Familiarise yourself with the application and limitations of the product, as well as potential hazards peculiar to the use of the thermometer.

 

9

   Keep the thermometer clean for best and safest performance.

 

9

   Store the thermometer in its protective cover when not in use.

 

9

   When not in use, store in a safe, dry, childproof area.

 

8

  

DO NOT 

use equipment for any purpose other than that for which it is designed.  

 

8

  

DO NOT

 allow untrained persons to operate the thermometer.

 

8

  

DO NOT 

use the thermometer to test objects above 250ºC.

2. 

 

INTRODUCTION

 

High precision digital thermometer with the sensor located in the tip of the stainless probe. Compact and lightweight measuring both °C  

 

and °F with hold function. Ideal for testing automotive air conditioning output. Powered by 1.5Volt cell (supplied).

 

Temperature Range: -40°C to +250°C (-40°F to +482°F)

3.  SPECIFICATION

Model No .................................................................... VS906

Temperature Range ........ -40°C to +250°C (-40°F to +482°F)

Focal Ratio ....................................................................... null

Accuracy .......................................................................±20%

4.  OPERATION

4.1.    

Remove the protective cover from the probe. The cover 

 

can, if required, be stowed on the other end of the 

 

thermometer body.

4.2.    

Turn the thermometer 

ON

 by pressing the 

ON/OFF

 button. The display will show all its symbols momentarily (as shown in fig.1) and  

 

then revert to zero. Once the tip of the probe has sensed the temperature the display will change from zero to that temperature.

4.3.    

Switch between Centigrade and Fahrenheit by pressing the 

ºC/ºF

 button.

4.4.    

Press the hold button to hold the current reading on the display (the 

‘HOLD’ 

symbol will begin to flash). To see the maximum reading of all  

 

the readings taken since switching on press 

HOLD

 again (

‘MAX’

 will flash on the display). To see the minimum reading of all the readings  

 

taken since switching on press 

HOLD

 again (

‘MIN’

 will flash on the display). To return to temperature measurement mode press

 HOLD 

 

 

again. This cycle can be repeated at any time.

4.5.    

Turn the thermometer 

OFF

 by pressing the 

ON/OFF

 button again. 

NOTE:

 Current readings are not held in memory when the  

 

 

thermometer is turned off.

4.6.    

If the thermometer is on but not in use it will turn itself off after approximately 20 mins.

4.7.    

If the measured temperature is over 250ºC the display will show 

‘H - -

 ‘.

 

If the measured temperature is under -40ºC the display will show 

‘L - - ‘.

5.  MAINTENANCE

5.1.    

After use, clean the probe with warm water and replace the protective cover.

5.2.    

If the display appears fuzzy or faded the battery should be replaced. (1.5V, LR44 or equivalent)

5.3.    

Battery  Removal

.

5.4. 

  

Remove the battery from the thermometer by rotating the circular battery compartment cover on the back of the casing. Lift off and tip  

 

out the battery.

VS906       Issue 2 (H, F) 13/07/18

Original Language Version

© Jack Sealey Limited