WARNING!

 

Be careful when inserting or removing the bore scope shaft into, and out of, the equipment  

 

under inspection.

 

Before and after use, check the bore scope for tears and abrasions.

 

Check the bore scope for correct lighting operation. If dim, or no lighting evident, replace the batteries.

 

Check the bore scope for smooth eyepiece rotation.

4.1. Note the location of the object to be inspected and determine a route to it. Bend the bore scope shaft to  
 

follow the route.

4.2. 

DO NOT

 bend the bore scope shaft tighter than Ø76mm.

4.3. 

DO NOT 

expose the bore scope housing to water or other liquids.

4.4. 

DO NOT

 insert the bore scope shaft into locations whose temperature is greater than 70°C.

4.5. 

DO NOT

 use the bore scope close to moving parts such as gears, fan blades or moving belts.

 

Battery Replacment

 

WARNING! Disconnect the bore scope prior to carrying out maintenance or battery replacement. 

 

Be careful when inserting, or removing, the battery pack so as not to strain or damage the connecting  

 

leads. 

REFER TO FIG 2.

3.1. Remove the battery housing door with a Phillips screwdriver.
3.2. Tilt the battery pack from the bottom of the bore scope handle and remove it.
3.3. Unclip the connector - if required - and replace the batteries.
3.4. Re-attach the connector and relocate the battery pack in the bore scope handle.
3.5. Replace the battery housing door using a Phillips screwdriver.

 

Lighting

3.6. The VS819900 bore scopes are equipped with integrated, solid-state LED lamps. These lamps are   
 

designed to be maintenance-free for the life of the instrument.

 

Cleaning and Storage

3.7.

 

Wipe the bore scope tip, shaft and housing with a clean, soft cloth to remove residue and moisture.

3.8. Wash the bore scope tip and shaft with a cleaning liquid and rinse with water, then dry.
3.9. Gently clean the Distal Tip lens and eyepiece with a lens cleaner such as isopropyl alcohol and a cotton  
 

bud.

NOTE: The bore scope MUST be completely dry prior to returning it to the storage case.

Fig 2

Fig 4

Fig 3

Bore Scope Model No: VS8199

00

2002/95/EC RoHS Directive

2002/96/EC WEEE Directive

93/68/EEC CE Marking Directive

Signed by Tim

 

Thompson

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

14th October 2006

 

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor
Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

  4. OPERATION

  5.  MAINTENANCE

VS819900

Issue: 1 - 14/10/08

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed here is in conformity with the following standards and directives.The 

construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.

Reviews: