4.  operation

4.1.    

to carry out test

4.1.1.   

prepare a container and remove approximately 1/10 of the volume of coolant. (fig.1).

4.1.2.   

open the radiator cap (make sure the radiator is cool before opening).

4.1.3. 

  

Remove cap to chamber 2, half fill with blue CO

2

 test liquid and replace cap.

4.1.4.   

install the rubber bulb, acrylic chamber and rubber cone adapter one after another.

4.1.5. 

  

Install tester device onto radiator’s filler neck. (Fig.2)

4.1.6.   

start engine and pump the rubber bulb continually to draw the steam from radiator and check if test liquid colour changes. (fig.3)

4.1.7. 

  

After testing, stop engine and remove cone adapter from radiator’s filler neck carefully. Refill radiator and replace cap.

4.1.8.   

pour the used test liquid into storage bottles and store each component in the carry case. test liquid  can be used 3 to 5 times.

     

                                                                                                                                  liquid                                                                     liquid

                                                                                                                                   Blue                                                                   Green/Yellow    

                                                                                                                                                                                                                                                                                                       

4.2.      

to read colour

4.2.1.   

test liquid  remains Blue (no co

2

 detected)------------------cylinder head/gasket in good condition.

4.2.2.   

test liquid turns Green (co

2

 detected) -----------------------cylinder head/gasket leaking.

4.2.3.    test liquid turns Yellow (large amounts co

2

 detected)---cylinder head/gasket leaking.

4.2.4.   

note:- 

the lighting in some work areas may affect the colour of the test liquid.  

5.   maintenance

5.1.    

Keep parts of leak detector clean and stored in the case provided. ensure test kit is kept in a secure, dry storage area and out of   

 

the reach of children.

Original Language Version

© Jack sealey limited

 Vs0062 | issue:1  05/05/16

 Fig.1

 Fig.2

 Fig.3

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

important:

 no liability is accepted for incorrect use of this product.

WarrantY:

 Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

Kempson Way, suffolk Business park,

Bury st. edmunds, suffolk.

ip32 7Ar

www.sealey.co.uk

[email protected]

01284 757500

01284 703534

Web

environmental protection 

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, 

taken to a recycling centre and disposed of in a manner which is compatible with the environment.

parts support is available for this product. to obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

Reviews: