8.1.

 Keep unit clean. Protect eye lens, display lid and prism to prevent scratching.

8.2.

 For best results an ambient temperature of 20°C for both refractometer and fluid being tested is recommended.

8.3.

 To test instrument accuracy, place distilled water on the prism and check that the LIGHT-DARK dividing line is   

 

level with the “WATERLINE”. If the reading is incorrect remove the black rubber cover from the calibration point  

 

(6). Insert the small supplied screwdriver into the hole in the calibration point. Turn the screwdriver whilst  

 

 

looking through the eyepiece until the waterline mark is on the light-dark dividing line.

8.4.

 After use and cleaning store in supplied foam lined and plastic case. 

7.1. 

Read the test procedure.

7.2. 

Refer to

 Scale D 

which

 

Indicates the percentage of urea to distilled water in AdBlu;

 32.5

 indicates the most    

 

desirable percentage of urea in the solution.

4.  ANTIFREEZE TEST 

4.1.

 Read the test procedure. 

4.2.

 For Propylene Glycol read the 

left side of

 

Scale

 

A

. For  Ethylene, OAT and G13 read the 

right side of 

 

Scale A

5.  WINDSCREEN WASHER 

5.1.

 Read the test procedure

5.2.

 Refer to 

Scale B

. Note: Variations in formulation of windscreen washer fluids may result in an average value    

 

for a variety of alcohol based anti-freeze mixtures, this test is therefore a guideline only. 

6.  BATTERY FLUID TEST 

6.1. 

Read the test procedure.

6.2.

 Refer to 

Scale C 

which Indicates the density of the battery fluid in kg per litre and the ranges for 

Recharge,    

 Fair

 

and

 

Good.

7.  ADBLU TEST 