background image

4.  OPERATION

4.1.   

 

Insert the end of the hose into a suitable container. Start operating the pump handle, the initial strokes should be rapid to help    

 

prime the pump, the pump should start to dispense the fluid within seven strokes of the pump handle.

 

8

   DO  NOT

 use undue pressure on the pump handle as this may cause the pump neck to fracture.

4.2.   

 

When pumping is completed, insert the nozzle into the nozzle holder. The handle may be locked into position using the latch on the  

 

pump body and a padlock.

5.  TROUBLESHOOTING

Problem

cause

Remedy

Pump does not dispense or flow is restricted

Pump not able to create adequate suction

Prime pump, see section 4.1

Pump is drawing in air instead of fluid

Tighten suction tube to pump inlet 

connection
extension seal failure between 

suction tube sections

Pump inlet is blocked

Remove suction tube and clean 

wire mesh screen at pump inlet

Leakage of fluid from pump handle piston

Damaged seal due to incompatible fluids

Return to your Sealey stockist

Pump outlet

Pump Handle

locking latch

Pump Inlet

Pump Body

Bung nut

dispensing

nozzle

nozzle

Holder

Telescopic 

Suction Tube

   fig.1

TP6918 Issue 2 25/01/19

Original Language Version

© Jack Sealey limited

Reviews: