Sealey TM103 Instructions Manual Download Page 7

tm103 | issue 3 07/10/16

Original Language Version

© Jack sealey limited

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

important:

 no liability is accepted for incorrect use of this product.

Warranty:

 Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

Kempson Way, suffolk Business Park,

Bury st. edmunds, suffolk.

iP32 7Ar

www.sealey.co.uk

[email protected]

01284 757500

01284 703534

environmental protection

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

Weee regulations

dispose of this product at the end of its working life in compliance with the eu directive on 

Waste electrical and electronic equipment (Weee). When the product is no longer required, it must be disposed

of in an environmentally protective way. contact your local solid waste authority for recycling information.

Battery removal

see section 1.4

under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential 

purchasers of products containing batteries (as defined within these regulations), that they are registered wih Valpak’s 

registered compliance scheme. Jack sealey ltd’s Batteries Producer registration number (BPrn) is BPrn00705.

parts support is available for this product. to obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

tm103 | issue 3 07/10/16

Original Language Version

© Jack sealey limited

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

important:

 no liability is accepted for incorrect use of this product.

Warranty:

 Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

Kempson Way, suffolk Business Park,

Bury st. edmunds, suffolk.

iP32 7Ar

www.sealey.co.uk

[email protected]

01284 757500

01284 703534

environmental protection

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

Weee regulations

dispose of this product at the end of its working life in compliance with the eu directive on 

Waste electrical and electronic equipment (Weee). When the product is no longer required, it must be disposed

of in an environmentally protective way. contact your local solid waste authority for recycling information.

Battery removal

see section 1.4

under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential 

purchasers of products containing batteries (as defined within these regulations), that they are registered wih Valpak’s 

registered compliance scheme. Jack sealey ltd’s Batteries Producer registration number (BPrn) is BPrn00705.

parts support is available for this product. to obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

Summary of Contents for TM103

Page 1: ...er capacitors in power supplies and disconnect the power when making resistance or diode tests WARNING Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live 8 8 DO NOT use the multimeter in a potentially explosive atmosphere DO NOT operate...

Page 2: ...ly check the fuses and battery to make sure that they are still good and that they are properly inserted 2 introduction High precision auto ranging multimeter Conforms with EN61010 1 CATIII 600V safety requirements for electrical equipment for measurement control and laboratory use Features temperature measurement capability data hold and auto power off function Double moulded housing with soft gr...

Page 3: ...ution Accuracy AC Current Auto ranging for uA mA Overload Protection 0 5A 250V and 10A 250V Fuse Frequency Range 50 to 400Hz Maximum Input 400mA dc or 400mA ac rms on uA mA ranges 10A dc or ac rms on 10A range 400 0µA 0 1µA 1 5 reading 5 digits 4000µA 1µA 1 8 reading 5 digits 40 00mA 10µA 400 0mA 100µA 10A 10mA 3 0 reading 7 digits Function Range Resolution Accuracy Resistance Auto Ranging Input P...

Page 4: ...ng a measurement the value exceeds the range you have selected Change to a higher range NOTE On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random reading This is normal and is caused by the high input sensitivity The reading will stabilise and give a proper measurement when connected to a circuit 4 1 MODE BUTTON 4 1 1 To select Diode Cont...

Page 5: ... the Mode button until DC shows in the display 4 7 6 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 4 7 7 Connect test leads in series with the circuit under measurement 4 7 8 Apply power to the circuit 4 7 9 Read the current in the display For mA DC measurements reset the function switch to successively lower mA DC positions to obt...

Page 6: ...nction switch to the C range 4 14 2 Insert the type K thermocouple into the thermocouple adaptor ensuring thermocouple positive is matched with the mark on the adaptor Insert the adaptor into the meter ensuring the negative pin is in the negative COM jack and the pin is in the positive Temp jack 4 14 3 Touch the Temperature Probe head to the part whose temperature you wish to measure Keep the prob...

Page 7: ... and or diagram please log on to www sealey co uk email sales sealey co uk or telephone 01284 757500 TM103 Issue 3 07 10 16 Original Language Version Jack Sealey Limited NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of this product WARR...

Reviews: