3.  SpeCifiCAtiON

model no:

 ....................................................................

tA305

display: .............3 3/4-digit lCd, with a max. reading of 3999

negative Polarity Indication:

 ........... negative sign “ - “ shown on the display automatically

over Range Indication:  .................  ol shown on the display

Jaw opening Capability: .............................................. 10mm

max. measurable Conductor: ......................................  10mm

Battery:  ........................... 1.5V battery, AAA or equivalent x2

low Battery Indication: ......................... shown on the display

operation environment:  ................... o°C to 40°C, < 75%RH 

Storage environment: ....................... -10°C- 50°C, < 85%RH 

Size: ............................................................226 x 71 x 38mm

Weight:  .......................................... 185g (including batteries}

AC voltage

Input impedance:..........................................................

10MΩ

Frequency range: ............................................. 40Hz - 400Hz

max. allowable input voltage: ..................................600V rms

Response: ................ Average, calibrated in rms of sine wave

        Note: 

The 400.0mV range is available only in manual range mode.

      

 

       dC voltage

Input impedance:............................

range 400.0mV:> 100MΩ

 

 

 

 

for the other ranges: 10MΩ

max. allowable input voltage: 600V dC

AC current

display: .............................sine wave rms, average response

Frequency range: ....................................................50 ˜ 60Hz

max. allowable input current: ....................................AC100A

Response: ................ Average, calibrated in rms of sine wave

T

emperature coefficient:

 ......................... ±0.3% of reading/°C

dC current

max. allowable input current: ....................................dC100A

T

emperature coefficient:

 ......................... ±0.3% of reading/°C

Original Language Version

© Jack Sealey limited

TA305  Issue 3  (3) -  12/12/18

Summary of Contents for TA305

Page 1: ...se or the battery cover 8 8 DO NOT operate with the battery cover or portions of the case removed or loosened 9 9 To avoid false readings which could lead to possible electric shock or personal Injury replace the batteries as soon as the low battery indicator appears 9 9 To avoid electric shock do not touch any naked conductor with hand or skin 8 8 DO NOT hold the meter anywhere beyond the finger ...

Page 2: ...ries AC voltage Input impedance 10MΩ Frequency range 40Hz 400Hz Max allowable input voltage 600V rms Response Average calibrated in rms of sine wave Note The 400 0mV range is available only in manual range mode DC voltage Input impedance range 400 0mV 100MΩ for the other ranges 10MΩ Max allowable input voltage 600V DC AC current Display sine wave rms average response Frequency range 50 60Hz Max al...

Page 3: ...s used to switch between autorange mode and manual range mode as well as to select desired manual range ii In continuity or diode test function this RANGE button is used to switch between continuity and diode test functions 7 HOLD Button Used to enter exit Data Hold mode 8 In dc current measurements this button is used for zeroing before measurement In other measurements this button can be used to...

Page 4: ...the reading on the display The polarity of the red test lead connection will be indicated as well Note To avoid electric shock or damage to the meter do not apply a voltage higher than 600V between terminals 5 5 Measuring DC Current 5 5 1 Set the function switch to the A position 5 5 2 If the display does not read zero press the button for zeroing 5 5 3 Press the trigger and clamp the jaws around ...

Page 5: ... to be tested 5 9 4 If the resistance is less than about 50Ω the built in buzzer will sound Note Before test disconnect all power to the circuit to be tested and discharge all capacitors thoroughly 5 10 Automatic Power Off 5 10 1 If the meter has not been used or the function switch rotated for about 15 minutes the meter will turn off automatically and go into Sleep mode 5 10 2 To wake the meter f...

Reviews: