InstructIons for:
LUX METER
MoDEL no :
TA065
thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
2. INTRODUCTION & SPECIFICATION
1.1.
GENERAL SAFETY
familiarise yourself with the applications, limitations, and potential hazards of the lux meter.
Keep the lux meter clean and in good condition.
If using to assess bright lights, apply common sense regarding eye protection.
DO NOT
operate the meter in a flammable or explosive atmosphere.
DO NOT
get the lux meter wet or use in damp or wet locations or areas where there is condensation.
DO NOT
use the lux meter for any purpose other than that for which it is designed.
DO NOT
allow untrained persons to operate the lux meter.
DO NOT
operate the lux meter when you are tired or under the influence of alcohol, drugs or intoxicating medication.
WARNING: The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions
and situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this
product, but must be applied by the operator.
High precision portable light meter with silicon photodiode and filter. Includes a large back-lit LcD screen that displays in either lux or
fc. Ideal for general use or ensuring sufficient lighting in workshop or office environments. features Max./Min., data hold, auto power off
and calibration procedure. supplied in storage case with 9V battery.
Model No:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TA065
range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-99999 lux /0-9999fc
Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±6%
sample rate: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 times per second
Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 x 9V (supplied)
Original Language Version
tA065 Issue: 1 - 19/02/14
fig.1
1 . . . Light sensor
2 . . . LcD Display
3 . . . on/off Key
4 . . . Hold Key
5 . . . Lux selector Key
6 . . . Max/Min Key
7 . . . fc selectorKey
8 . . . Backlight Key
9 . . . Light sensor cap
© Jack sealey Limited