background image

Declaration of Conformity 

We, the sole importer into the UK, declare that the products listed below are in conformity with the following EEC standards and directives

SUBMERSIBLE WATER PUMP

Models: SWP30, SWP30A, SSWP40,

SSWP40A, SWP60, SPW60A.

73/23/EEC Low Voltage Directive

89/336/EEC EMC Directive

BSEN 60335-2-41

7th August 2000

Signed by Mark Sweetman

The construction file for these products are held by the Manufacturer and may be inspected, by a national authority,

upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. 

Sole importer into the UK

of Sealey Power Products.

a. The thermal circuit

breaker cuts in as the 

motor has overheated.

b. Motor operates but 

there is no suction.

c. Reduced water volume 

for level of water

d. The pump will not start

or suddenly stops 

during operation.

10. No electrical power.

11. Float not working

12. Circuit breaker has triggered.

13. Impeller is jammed.

10. Check cable, plug and fuse.

11. Contact authorised service agent.

12. See (a) above.

13. Clean the pump.

7. Discharge pipe bent, or pinched.

8. Discharge pipe too narrow.

9. Pump partially blocked.

7. Straighten pipe

8. Use wider diameter pipe.

9. Clean pump.

1. The water level is too low

2. Intake blocked, impeller jammed.

3. Temperature of inlet water exceeds 35

O

4. Water level below min suction depth.

5. Air bubbles in pump accumulated during submersion, or because float is incorrectly 

positioned so pump does not stop at min level and sucks in air. 

6. Clogged intake filter or discharge pipe

4. Stop the pump.

5. Release air by inclining the pump and re-immersing it in water.

6. Remove dirt, and clean the unit.

1. Sink the pump deeper, or allow to cool before continuing use.

2. Check and clean.

3. Reduce water temperature.  Allow the circuit breaker to cool for approx 25mins before restarting.

TROUBLESHOOTING

Sole UK Distributor, 

Sealey Group

, Bury St. Edmunds, Suffolk.

01284 757500

[email protected]

www.sealey.co.uk

01284 703534

e-mail

Web

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required 

for any claim. 

INFORMATION: 

Call us for a copy of our latest catalogue and promotions on 01284 757525 and leave your full name and address including postcode.

SWP30,30A,40,40A,60,60A. - 2 - 241103

4. MAINTENANCE

p

p

WARNING! With the exception listed below, all pump, float and electrical cable service maintenance 

and repair must only be undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate your 

warranty.

p

p

WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.

4.1

Keep all parts of the pump clean. Rinse, drain and allow to dry before storing.

4.2.

Regularly check the water inlet at the base of the pump to ensure there are no blockages. To access the impeller carefully undo the base screws and 

remove base and clean the impeller, replace the base ensuring that the “O” - ring is correctly located. DO NOT dismantle any other part of the unit.

Note: 

The pump has a self lubricating oil-less motor, but a small amount of sealant is used to seal the unit. Should the pump seal be damaged the

sealant may leak and appear as a oily film on the surface of the water. The sealant is harmless to humans, but may effect pond life. In such an

eventuality, switch the pump off, remove it from the water and clear the oily film. Contact your local Sealey service agent for pump repair.