6.1.  Wire feed unit 

 

Check the wire feed unit at regular intervals. The feed roller wire guide plays an important part in obtaining consistent results. Poor wire feed affects  

 

 

welding. Clean the rollers weekly, especially the feed roller groove, removing all dust deposits.

6.2.   Cleaning / Changing feed roller 

 

IMPORTANT:

 The feed roller groove must correspond to the wire size.

 

There are two grooves on the feed roller, 0.6mm and 0.8mm, (optional 1.0mm roller available Part No: 120/722629). Always use the groove on the outside  

 

of the roller (the groove nearest to you). To remove the feed roller, undo the two screws and remove the plastic cover (fig.4b). 

 

Clean the roller or change if damaged, refit with the groove corresponding to the wire in use on the outside and then replace the plastic cover.

6.3.   Torch

 

Protect the torch cable assembly from mechanical wear. Clean the liner from the machine forwards by using compressed air. If the liner is clogged it must   

 

be replaced. 

6.4.   Contact Tip 

 

To remove/replace tip follow steps in 3.5.6./3.5.9. very carefully.

 

The contact tip is a consumable item and must be replaced when the hole becomes enlarged or oval. The contact tip 

MUST

 be kept free from spatter to ensure  

 

an unimpeded flow of gas. 

6.5.   Gas Cup 

 

To remove/replace cup follow steps in 3.5.6./3.5.9. very carefully.

 

The gas cup must also be kept clean and free from spatter. Build up of spatter inside the gas cup can cause a short circuit at the contact tip which will result  

 

in either the fuse blowing on the printed circuit card or expensive machine repairs. To keep the contact tip free from spatter, we recommend the use of Sealey  

 

anti-spatter spray (MIG/722307) and a nozzle cleaning tool (AK107) available from your Sealey Dealer.

6.6.   Replacing the liner

 

Wind the wire back on to the spool and secure it. Unscrew the torch from the machine and undo the brass nut. The liner should now be visible. Pull it out and  

 

replace with a new one. 

Note:

 If using 1.0mm wire the optional liner (120/722689) will be required.

6.7.   Changing gears

 

An inexperienced welder can allow spatter to build up in the tip and shroud. In severe cases this can block the wire feed causing gear stripping in the drive  

 

motor. To check if the gears are worn, depress the button on the torch with the set switched on. If the gears are worn, a grating sound will be heard coming  

 

from the wire feed motor and you may also observe the feed roller vibrating instead of rotating. Should this be the case, open the gearbox, remove the worn  

 

or damaged gears and replace with new ones.

  6.  MAINTENANCE

Supermig250

Issue No: 1 - 03/03/09

  7.  ELECTROMAGNETIC COMPATIBILITY

7.1.

  THIS EqUIPMENT IS IN CONFORMITY WITH THE EUROPEAN STANDARD ON THE ELECTROMAGNETIC COMPATIBILITY OF ARC WELDING  

 

 

EqUIPMENT AND SIMILAR PROCESSES (e.g. ARC AND PLASMA CUTTING).

7.2.

 

Protection against interference. (E.M.C.)

 The emission limits in this standard may not, however, provide full protection against interference to radio and   

 

television reception when the equipment is used closer than 30m to the receiving antenna. In special cases, when highly susceptible apparatus is being    

 

used in close proximity, additional mitigation measures may have to be employed in order to reduce the electromagnetic emissions. At the same time there  

 

could occur some potential difficulties in having electromagnetic compatibility in a non-industrial environment (e.g. in residential areas). Therefore it is most  

 

important that the equipment is used and installed according to the following instructions.

7.3.

 

Installation and use. 

The user is responsible for installing and using the equipment according to these instructions. If electromagnetic disturbances are    

 

detected, then it shall be the responsibility of the user of the equipment to resolve the situation with the technical assistance of the supplier. In some cases  

 

this remedial action may be as simple as earthing the circuit (see Note). In other cases it could involve constructing an electromagnetic screen, enclosing   

 

the welding power source and the work, complete with associated input filters. In all cases the electromagnetic disturbances shall be reduced to the point   

 

where they are no longer troublesome.

 

Note:

 The welding/cutting circuit may or may not be earthed for safety reasons. Changing the earthing arrangements should only be authorised by a  

 

 

person who is competent to assess whether the changes will increase the risk of injury, e.g. by allowing parallel welding/cutting circuit return paths which    

 

may damage the earth circuits of other equipment. Further guidance is given in IEC 974-13 ’Arc Welding Equipment - Installation and Use'.

7.4.

 

Assessment of area.

 Before installing the equipment the user shall make an assessment of potential electromechanical problems in the surrounding area.  

 

The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding    

 

area may extend beyond the boundaries of the premises.

 

The following shall be taken into account:

 

a)  Other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the welding equipment.

 

b)  Radio and television transmitters and receivers.

 

c)  Computer and other control equipment.

 

d)  Safety critical equipment, e.g. security monitoring of industrial equipment.

 

e)  The health of people in the vicinity, e.g. persons fitted with a pacemaker or hearing aid.

 

f)  Equipment used for calibration or measurement.

 

g)  The immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This    

 

 

may require additional protective measures. 

 

h)  The time of day that welding and other activities are to be carried out.

7.5.

 

Mains supply.

 The equipment should be connected to the mains supply according to these instructions. If interference occurs, it may be necessary to take  

 

additional precautions such as filtering of the mains supply. Consideration should also be given to shielding the supply cable of permanently installed  

 

 

equipment in metallic conduit or equivalent. This shielding should be connected to the power source so that good electrical contact is maintained between  

 

the conduit and the welding power source enclosure.

7.6.

 

Maintenance of the  equipment.

 The equipment should be routinely maintained according to these instructions. All access and service covers should be   

 

closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those  

 

 

changes and adjustments covered in these instructions. In particular, the spark gaps of any arc striking and stabilising devices should be adjusted and  

 

 

maintained according to the instructions.

7.7.

 

Cables. 

The welding/cutting cables should be kept as short as possible and should be positioned close together, running at or close to the floor level.

7.8.

 

Equipotential bonding.

 Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered. However, metallic    

 

components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these metallic components and the  

 

 

electrode at the same time. The operator should be insulated from all such bonded metallic components.

7.9.

 

Earthing of the workpiece. 

Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size and position, e.g.   

 

ship’s hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to  

 

prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment. Where necessary, the connection of    

 

the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding  

 

should be achieved by a suitable capacitance, selected according to national regulations.

7.10.

 

Screening and shielding.

 Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference.  

 

Screening of the entire welding/cutting installation may be considered for special applications.

Summary of Contents for SUPERMIG250

Page 1: ...INSTRUCTIONS FOR SUPERMIG WELDER SUPERMIG250 MODEL No Supermig250 Issue No 1 03 03 09 ...

Page 2: ... will invalidate the warranty Use an air hose to regularly blow out any dirt from the liner and keep the welder clean for best and safest performance Check and spray the gas cup and contact tip regularly with anti spatter spray which is available from your Sealey dealer Locate the welder in a suitable work area Ensure that the area has adequate ventilation as welding fumes are harmful Keep work ar...

Page 3: ...locate on the two end springs fig 4a 3 5 3 Undo the wire lock screw and lift the wire feed lever up to the right fig 5a The outer groove of the roller must match the size of the wire to be used If required undo the two screws and turn the roller around so that the appropriate groove is outermost 3 5 4 Free the end of the wire from the reel do not allow wire to uncoil and remove the distorted end w...

Page 4: ...at an angle of about 20 from the vertical with the nozzle shroud angled forward 4 1 5 Welding aluminium To weld aluminium use Argon gas 0 8mm Contact Tip 120 722556 0 8mm Aluminium Wire MIG 2 KAL08 4 1 6 Spot welding Spot welding may be carried out as shown in fig 9 It will be necessary to fit a spot welding gas cup Sealey Part No 120 722687 a Overlapping metal sheets with a maximum thickness of 0...

Page 5: ...ete with associated input filters In all cases the electromagnetic disturbances shall be reduced to the point where they are no longer troublesome Note The welding cutting circuit may or may not be earthed for safety reasons Changing the earthing arrangements should only be authorised by a person who is competent to assess whether the changes will increase the risk of injury e g by allowing parall...

Page 6: ...e workpiece Section 4 Torch too far from or at wrong angle to work The distance from gas cup to workpiece should be 8 10mm Gas leak Check hoses connections and torch assembly Faulty electrovalve Clean out or replace Electrode sticking in gas cup nozzle Worn or defective gas cup nozzle Replace gas cup nozzle Section 6 Electrode deformed Check roller tension Section 3 Wire speed too slow See recomme...

Page 7: ... ...

Page 8: ... ...

Page 9: ...95 EC Low Voltage Directive 2004 108 EC EMC Directive 93 68 EEC CE Marking Directive 2002 95 EC RoHS Directive 2002 96 EC WEEE Directive We the sole importer into the UK declare that the product listed below is in conformity with the following standards and directives The construction file for this product is held by the Manufacturer and may be inspected by a national authority upon request to Jac...

Reviews: