Sealey STW292 Instructions Download Page 2

4.5. 

Selecting Peak or Trace.

 

Selecting Peak:

4.5.1.  Press and release Peak/Trace button (fig.5), the LCD  

 

panel shows “PtoP“, after 2 seconds the LCD panel  

 

shows 00.0.

 

Selecting Trace:

4.5.2.   Press and release Peak/Trace button (fig.5), the LCD  

 

panel shows “trACE“, after 2 seconds the LCD panel  

 

shows 0.00.

4.6. 

Memory.

4.6.1.  Store reading must be under the  “PtoP” mode.

4.6.2.  Press “Mem” button for at least 1 second and release

 

(fig.6), the LCD display shows the memory number  

 

“P01” then the torque value for this.

4.6.3.   Pressing the “Mem” button again for at least 1 second,  

 

the LCD display shows the memory number “P02”  

 

and then the torque value. Repeat to cycle through all  

 

memory values (“P01” is the latest reading, “P50” is the  

 

oldest). The digital torque adaptor stores the last 50  

 

torque value readings.

4.7.   Turning Adaptor Off.

4.7.1.  If the digital torque adaptor is not used for 80 seconds,  

 

it will automatically switch off, otherwise manually turn  

 

it off by pressing and releasing the power button (fig.7).

4.2. 

Power On.

4.2.1.  Press the Power button once (fig.2) to turn the  

 

digital torque adaptor on. The display will initially show  

 

“trACE” or “PtoP”. After 2 seconds the LCD panel will  

 

show “00.0”.

NOTE:

 If left unused, the digital torque adaptor will 

 

automatically turn off after 80 seconds.

4.2.2.  Ascertain the correct size and type of socket for the 

 

fixing to be tightened and attach it to the square drive  

 

connector (3/4”) at the base of the adaptor.

4.2.3.  Insert the required ratchet wrench/drive bar into the  

 

socket at the top of the adaptor. 

DO NOT

 use a tool  

 

that will allow you to apply excessive force through the  

 

adaptor.

4.3. 

Selecting unit of measurement.

4.3.1.  Press Mem and Peak/Trace buttons together (fig.3) and  

 

release to select different units of torque measurement  

 

(Nm/lb.in/kg.m) in rotation.

4.3.2.  When the units are changed, the target setting will also  

 

be changed to the new unit value.

4.4. 

Setting the target torque value. 

4.4.1.  To increase the value, press and hold the (+) button 

 

(fig.4), the target value will display for 10 seconds then  

 

the LCD will display 0.00.

4.4.2.  To decrease the value, press and hold the (-) button

 

(fig.4), the target value will display for 10 seconds then  

 

the LCD will display 0.00.

NOTE:

 In use, when the torque is approaching within 20% of  

 

the target value, the red LED will flash and an   

 

intermittent buzzer warning will be heard, indicating that  

 

the target torque value is nearing. When the target  

 

torque value is reached, the red LED will illuminate and  

 

the buzzer will sound. Immediately stop applying  

 

pressure to the fixing.

fig.2

fig.4

fig.5

fig.6

fig.7

fig.3

5.1.  Battery care and use.

5.1.1.  Keep the batteries dry at all times.

5.1.2.  Do not combine used batteries with new ones or mix  

 

battery types.

5.1.3.  Insert/remove the batteries carefully as described in   

 

Section 4.1.1.

5.1.4.  Never use a battery if it is cracked, broken or leaking.

5.1.5.  Never heat or incinerate batteries.

5.1.6.  See battery disposal information below.

5.1.7.  If the digital torque adaptor is not being used for a  

 

longer period of time, remove the batteries to prevent  

 

damage from leakage.

5.2.  Calibration.

5.2.1.  Periodic calibration is required for this product, contact  

 

your Sealey dealer for details.

5.3. 

Use only a damp cloth for cleaning. Never use any type  

 

of liquid, aerosol cleaner, or any type of organic solvent.

5.  MAINTENANCE

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for

 

any claim. 

INFORMATION: 

Call us for a copy of our latest catalogue on 01284 757525 and leave your full name and address including your postcode.

01284 757500
01284 703534

[email protected]

www.sealey.co.uk

Web

STW292     Issue No.1    26/07/12

Original Language Version

© Jack Sealey Limited

 

Do not expose battery to intense heat or fire as  

 

this could cause an explosion.

 

Battery Removal: Refer to Section 4.1.1.     

 

ONLY

 dispose of or recycle according to local  

 

authority regulations. Under the Waste Batteries  

 

and Accumulators Regulations 2009, Jack  

 

Sealey Ltd are required to inform potential  

 

purchasers of products containing batteries (as  

 

defined within these regulations), that they are  

 

registered with Valpak’s registered compliance  

 

scheme. Jack Sealey Ltd’s Batteries Producer  

 

Registration Number (BPRN) is BPRN00705.

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

Reviews: