INSTRUCTIONS FOR:
DIGITAL TORQUE ADAPTOR
3/4” Sq. Drive - 100 - 500Nm
MODEL No:
STW292
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS
AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE
TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP
INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these
instructions and properly maintained, give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
3. SPECIFICATION
2. INTRODUCTION
4. OPERATION
Designed for use with a standard ratchet or breaker bar. Ideal
for work around the engine bay and the tightening of wheel
nuts to factory specifications. Large LCD display with LED/
audible alarm indicating achieved and target torque levels.
Selectable readings in Nm, lb.ft or kg.m and accurate to ±2%
of stated capacity. Memory stores up to 50 readings and
features auto shut off after 80 seconds. Supplied with test
certificate and storage case.
STW292 Issue No.1 26/07/12
Original Language Version
© Jack Sealey Limited
NOTE:
DO NOT
press the Mem and Power buttons at the
same time as this will enter calibration mode.
4.1.
Preparation.
4.1.1. Unscrew the four cross-head screws holding the rear
battery cover and remove the battery cover (fig.1).
Install two AA batteries, ensuring correct polarity. Refit
the battery cover and refit and tighten the four
cross-head screws.
NOTE:
When battery power is low, a low battery icon will be
displayed.
NOTE:
DO NOT
use the digital torque adaptor when the
battery is in a low state of charge as this will affect the
torque adaptor’s accuracy.
WARNING! DO NOT
use the digital torque adaptor if
damaged or thought to be faulty.
DO NOT
apply force to the digital torque adaptor when
the power is off. Always turn it on before using it,
otherwise it will be damaged.
DO NOT
turn off the digital torque adaptor while torque
force is being applied to it.
DO NOT
exceed the permitted maximum torque value.
To do so will cause it to break.
DO NOT
subject the 3/4” connectors to any force other
than a rotational one.
Ensure that all components including all adaptors,
extensions, drivers and sockets are rated to match or
exceed the torque being applied.
Observe all equipment, system and manufacturer’s
warnings, cautions and procedures when using this
digital torque adaptor.
Use the correct size socket for the fixing.
DO NOT
use sockets that are worn or cracked.
Check that the digital torque adaptor capacity matches or
exceeds each application before proceeding.
Ensure all workshop safety rules, regulations, and
conditions are complied with when using this digital
torque adaptor.
Maintain correct balance and footing. Ensure the floor is
not slippery and wear non-slip shoes.
Keep children and unauthorised persons away from the
working area.
DO NOT
press, pressure, or damage the LCD display.
DO NOT
use near strong magnetic fields.
DO NOT
subject to excessive force or shocks.
DO NOT
drop or throw the digital torque adaptor.
DO NOT
leave the digital torque adaptor in any place
exposed to excessive heat, humidity or direct sunlight.
DO NOT
use organic solvents such as alcohol or
thinners for cleaning.
DO NOT
submerge in water or any other liquid.
DO NOT
disassemble the digital torque adaptor.
To ensure accurate measurement, periodic re-calibration
is necessary.
After use, clean with a soft dry cloth and store in a safe,
dry, childproof location away from any heat sources.
Avoid any dusty, damp or humid conditions.
MODEL:
STW292
Range:
100-500Nm/73.8-369lb.ft/10.19-50.98kg.m
Accuracy:
±2%
Resolution:
0.1
Drive:
3/4” Sq. Drive
Units:
Nm/lb.ft/kg.m
Size (L x W):
110mm x 56mm
Weight:
570g
Operating Modes:
Trace & Peak
Memory Space:
50
Battery:
2 x AA Type
Battery Life:
Up to 110 Hours
Operating temp:
-10 ~ 60ºC/13.9 ~ 139.9ºF
Storage temp:
-20 ~ 70ºC/-4 ~ 157.9ºF
Humidity:
15 ~ 90% Non-condensing
fig.1