5. MAINTENANCE

5.1. 

  

PAPR

 

CLEANING:

5.1.1. 

  

Detach the battery pack, hose assembly and the blower. Inspect all parts for damage. Replace all damaged parts prior to storage   

 

or next use.

5.2. 

  

BLOWER

5.2.1. 

  

Clean the outer surfaces of PAPR assembly and battery pack with a soft cloth dampened in a solution of water and mild, pH  

 

 neutral 

detergent.

 

  

DO NOT

 immerse the blower or battery pack in water.

 

  

DO NOT

 use solvents or abrasive cleaners.

 

  

DO NOT

  attempt to clean the interior of the blower with compressed air or vacuum.

 

   Ensure the electrical contacts of the blower and battery pack are dry.

5.3. 

  

HOSE ASSEMBLY

5.3.1.   

Clean the connection joints on the hose assembly with water and a mild detergent solution.

 

 

NOTE:

 The hose assembly can be immersed in water for cleaning.

5.3.2. 

  

Air dry or dry by connecting to the blower unit and blow dry the hose.

 

 

NOTE:

 The inside of the hose must be completely dried prior to use or storage.

5.4. 

  

HEPA FILTER

5.4.1. 

  Remove 

the 

fi

 lter cover and inspect the 

fi

 lter.

5.4.2. 

  

Replace if excessively dirty.

5.5. 

  

CHANGING THE VISOR

5.5.1.   

Release the stud from the bottom of the outside front of the face shield.

5.5.2. 

  

Release the two tags on the outside bottom edge of the visor.

5.5.3. 

  

Release the two sides and pull downwards to release the visor.

5.5.4. 

  

Fitting a new visor is the reverse of the above.

5.6. 

  

CLEANING AND DISINFECTION THE VISOR

 

  DO 

NOT

 use abrasive materials.

5.6.1. 

  

The lens is not scratch resistant. Be very careful when wiping, keep this to a minimum and use a soft, non-friction cloth.

5.6.2. 

  

Clean with a soap and warm water or with ordinary household disinfectant.

5.7. 

  

INSPECTION

5.7.1.   

Face shields should be periodically inspected and cleaned. If it is damaged , pitted or anything that seriously a

 ects the vision  

 

 

through it, the lens must be replaced.

5.8. 

  

STORAGE

5.8.1. 

  

If the face shield with powered air purifying respirator is not to be used for an extended period, remove the 

fi

 lter and battery pack   

 

and store in its original packaging in a clean, dry, cool place free of solvent based vapours.

5.8.2. 

  

Face shield: Good storage conditions are very important for the service life of the face shield. It should be stored at temperatures   

 

between 5ºC to 40ºC and 90% relative humidity. It should be kept away from solvents, solvent vapours or any corrosive materials,  

 

because the protection e

 ect of the face shield may be seriously reduced.

5.8.2.1. 

   When not in use it is recommended that the face shield is stored in its original packaging in a clean, dry, cool place.

 

 

NOTE:

 Safety visor screen (SSP80PAPR.13) only, has a product life of 2 years from date of purchase.

6. TROUBLESHOOTING

FAULT

POSSIBLE SOLUTION

Blower does not supply air to hood

1. Press ON/OFF to start blower
2. Recharge battery
3. Verify battery is properly connected to blower
4. Remove blockage from blower outlet and breathing tube

Battery pack’s charge lasts less than expected

1. Ensure battery pack is fully charged
2. Replace battery
3. Replace charger
4. Check the air 

fi

 lter (HEPA 

fi

 lter & Foam pre

fi

 lter), and replace it if necessary

Blower cannot be turned o

 

Press ON/OFF button for one second

Battery red level light is 

fl

 ashing

Charge or replace the battery

Danger light is on, alarm sounds or blower vibrates

Check the blower air 

fl

 ow as section 4.11

SSP80PAPR  Issue 1 11/08/21

Original Language Version