4.3.    

RATCHET

4.3.1.   

Attach the required socket to the tool and set the direction of rotation according to the task being undertaken (fig.1).

4.3.2.   

The ratchet can be used in both powered and manual modes. When the switch lock is pushed backwards into the handle, the on/off  

 

switch is disabled and the ratchet can be used in manual mode.

  

NOTE: 

The motor has over-torque protection in which a clutch mechanism activates a tactile vibrating response in the unit. This alerts  

 

the user to switch to manual mode (i.e. push switch lock rearwards).

4.3.3.   

The battery state, whilst in use, is indicated by the battery level indicator (fig.1 and the table above).

5.  MAINTENANCE

 

‰

  

WARNING: 

Always disconnect the battery before carrying out any inspection, maintenance or cleaning.

5.1.    

GENERAL  INSPECTION

5.1.1. 

  

Regularly check that all features are in working order. 

 

5.1.2.   

CLEANING

 

‰

  

WARNING:

 Always wear protective equipment including eye protection and gloves when cleaning this tool.

5.1.3. 

  

Keep your tool clean at all times. Dirt and dust will cause internal parts to wear quickly and shorten the device’s service life.

5.1.4. 

  

Clean the body of your machine with a soft brush, or dry cloth.

5.1.5.   

Never use caustic agents to clean plastic parts. If dry cleaning is not sufficient, a mild detergent on a damp cloth is recommended.

5.1.6.   

Water must never come into contact with the tool. Ensure the tool is thoroughly dry before using it.   

5.1.7. 

  

If available, use clean, dry compressed air to blow through the ventilation holes (where applicable).

5.2.    

LUBRICATION

5.2.1. 

  

Lightly lubricate all moving parts at regular intervals with a suitable lubricant.

5.3.    

STORAGE

5.3.1. 

  

Store this tool carefully in a secure, dry place out of the reach of children.

 

fig.1

B

attery level indicator light

Continuous green

P

ower status normal, battery 50 - 100%

Continuous blue

P

ower status normal, battery 20 - 50%

F

lashing blue

C

harging required, battery at 5 - 20%

Continuous red

C

harging required, battery <5%

F

lashing red

O

ver current protection active. Auto shut off

F

lashing green

O

ver temp. protection active. Auto shut off

B

attery pack temp. exceeded discharge rate.

Original Language Version

© Jack Sealey Limited

S

PR001, SPR002   Issue 2 (2,3)  04/03/20

Summary of Contents for SPR001

Page 1: ... only are marked with the Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight 8 DO NOT connect either wire to the ear...

Page 2: ...et Wrench with your finger on the power switch Keep switch lock in the locked position 8 DO NOT use the Ratchet Wrench for a task it is not designed to perform 8 DO NOT operate the Ratchet Wrench when you are tired or under the influence of alcohol drugs or intoxicating medication 8 DO NOT get the Ratchet Wrench or battery charger wet or use in damp or wet locations 2 INTRODUCTION The Sealey Power...

Page 3: ...l times Dirt and dust will cause internal parts to wear quickly and shorten the device s service life 5 1 4 Clean the body of your machine with a soft brush or dry cloth 5 1 5 Never use caustic agents to clean plastic parts If dry cleaning is not sufficient a mild detergent on a damp cloth is recommended 5 1 6 Water must never come into contact with the tool Ensure the tool is thoroughly dry befor...

Page 4: ...s subject to the vibration testing section of the Machinery Directive 2006 42 EC This tool is to be operated in accordance with these instructions Measured vibration emission value a 1 263 m s Uncertainty value k 0 618 m s Please note that the application of the tool to a sole specialist task may produce a different average vibration emission We recommend that a specific evaluation of the vibratio...

Reviews: