background image

Original Language Version

 © Jack Sealey Limited

SPI3S    Issue: 1 - 21/05/14

7.1. 

Battery Percentage and Charge Time

 

This charger adjusts the charging time in order to charge the battery completely, efficiently and safely. The microprocessor 

 

automatically performs the necessary functions. This section includes guidelines that can be used to estimate charging times. Use the  

 

following table to determine the time it will take to bring a battery to full charge.

 

First, identify where your battery fits into the chart.

 

CCA = Cold Cranking Amps     Ah = Amp Hour

 

Find your battery’s rating on the following chart, and note the charge time given for each charger setting. The times given are for 

 

batteries with a 50% charge prior to recharging. Add more time for severely discharged batteries.

 7.  CHARGE TIME

 8.  DISPLAY MESSAGES

 9.  MAINTENANCE

8.1.

 

SELECT BATTERY TYPE (No LED lit) – Waiting for user to select battery type.

8.2.       

LEAD-ACID BATTERY-PRESS AGAIN FOR LITHIUM ION (No LED lit) – Charging will begin for lead-acid battery type. Press again to   

             change to lithium ion battery type.

8.3. 

CONNECT CLAMPS (No LED lit) – Plugged into the mains supply without the clamps connected to a battery.

8.4. 

WARNING CLAMPS REVERSED (No LED lit) – Plugged into the mains supply and the clamps are connected backwards to a 12V

 battery.

8.5. 

ANALYZING BATTERY (Green LED lit) – Plugged into the mains supply, and when first connected to a 12V battery correctly.

8.6. 

CHARGING 12V – XX% (Green LED lit) – Plugged into the mains supply and correctly connected to a discharged 12V battery.

8.7. 

FULLY CHARGED AUTO MAINTAINING (Green LED pulsing) – Plugged into the mains supply and correctly connected to a fully  

 

 

charged 12V battery.

8.8. 

CHARGE ABORTED-BAD BATTERY (Green LED flashing) – Circumstances that could cause an Abort situation during charging:

 

• The battery is severely sulphated or has a shorted cell and can’t reach a full charge.

 

• The battery is too large or there is a bank of batteries and it doesn’t reach full charge within a set time period.

 

Circumstances that could cause an Abort situation during maintain:

 

• The battery is severely sulfated or has a weak cell and will not hold a charge.

 

• There is a large draw on the battery and the charger has to supply its maximum maintain current for a 12 hour period to keep the 

 

battery at full charge.

9.1.

 

Cleaning and user maintenance should be carried out by competent persons.

9.2.

 

After use and before performing maintenance, unplug and disconnect the battery charger.

9.3.

 

Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery connectors, cords, and the charger case.

9.4.

 

Ensure that all of the charger components are in place and in good working condition, for example, the plastic boots on the battery  

 

 clips.

9.5.

 

Servicing does not require opening the unit, as there are no serviceable parts.

9.6. 

 

All other servicing should be performed by qualified service personnel.

9.7.

 

If the mains cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons, in order to avoid  

 

a hazard.

9.8.

 

Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the mains.

9.9. 

Store inside, in a cool, dry place.

9.10.

  Do not store the connectors clipped together, on or around metal, or clipped to cables.

9.11.

  If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cables,

 

connectors  and charger. Failure to do so could result in personal injury or property damage.

Summary of Contents for SPI3S

Page 1: ...ected The cable core section is important and should be at least 1 5mm but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets we recommend the use of 2 5mm section cable If extension reel is to be used outdoors ensure it is marked for outdoor use IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY NOTE THE SA...

Page 2: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision SPI3S Issue 1 21 05 14 Original Language Version Jack Sealey Limited 2 INTRODUCTION 3 SPECIFICATION 4 PREPARATION Fully automatic microprocessor co...

Page 3: ...o the carburettor fuel lines or sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block 4 9 6 For a positive earthed vehicle connect the NEGATIVE BLACK clip from the battery charger to the NEGATIVE NEG N non earthed post of the battery Connect the POSITIVE RED clip to the vehicle chassis or engine block away from the battery DO NOT connect the clip to the carburetto...

Page 4: ...minal 6 4 4 Connect the negative connector ring to the negative NEG N battery terminal 6 4 5 Replace and tighten the nuts to secure them 6 4 6 Connect the ring connector cable assembly to the charger Take care to keep both wires and plug away from hot and moving parts 6 4 7 Plug the charger power cable into a mains outlet Make sure to place the charger on a dry non flammable surface 6 4 8 Select t...

Page 5: ...tery 8 8 CHARGE ABORTED BAD BATTERY Green LED flashing Circumstances that could cause an Abort situation during charging The battery is severely sulphated or has a shorted cell and can t reach a full charge The battery is too large or there is a bank of batteries and it doesn t reach full charge within a set time period Circumstances that could cause an Abort situation during maintain The battery ...

Page 6: ...the condition The green LED will be lit when the charger is checking the display shows ANALYzING of the battery condition of the battery This is normal BATTERY Green LED is flashing and The battery is too large for the charger You need a charger with a higher amp rate display shows CHARGE ABORTED BAD BATTERY The battery voltage is still below 10V after Have the battery checked 2 hours of charging ...

Reviews: