background image

DIGITAL FEED DISPLAY FOR SM3002

 

  

 

MODEL: 

SM3002DFD

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE 

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

INSTRUCTIONS FOR:

1. INTRODUCTION

Digital display for the cross slide and the compound tool rest to replace the standard graduated scales. These LCD units improve accuracy, save 

reading time and minimise errors. Imperial or Metric readings may be selected and the reading can be zeroed at any point. Three decimal place 

(Metric) and four decimal place (Imperial) displays with an accuracy of ± 0.025mm/0.001””. 

2. CONTENTS

3. 

INSTALLATION 1

3.1 Loosen the compound rest gibs 

(fig 1a) and crank the compound rest 

feed handle anticlockwise to remove the 

top of the compound rest from the 

compound rest bottom. 

3.2 Undo the handle screw of the graduated 

scale (fig 2a) and remove the spring clip 

and scale (fig 2b). Remove the compound 

rest screw retainer (fig 2c) (retaining the 

fixing screws for future use) and remove 

the compound rest feed screw. 

3.3 Remove the two large hex screws 

(fig 3a) (retaining them for future use). 

Remove the compound rest 

bottom (fig 3b) from the cross slide. 

3.4 Move the protractor (fig 4a) to the 

new compound rest bottom (fig 4b) and 

slide the compound rest top (fig 4c) a 

short way onto the new compound rest 

bottom, being sure to leave the two large 

screw holes uncovered. 

3.5 Screw the compound rest back onto 

the cross slide using the two large hex 

screws. Adjust the gib screws so that the 

compound rest may be moved by hand 

but with some resistance.                        

3.6 Screw the new compound rest feed 

screw into the compound rest bottom. 

Installing the Compound Rest digital display. 

1. Cross slide feed screw

2. Compound rest feed screw

3. Screws and spacers

4. Cross slide screw retainer

5. Cross slide feed nut 

6. Compound rest screw retainer

7. Compound rest bottom

8. Digital displays 

1

2

6

5

4

7

8

3

fig 1

fig 2

fig 3

fig 4

fig 5

fig 6

a

c b a

a b

a

b

c

© Jack Sealey Limited

    Original Language Version 

  SM3002DFD     Issue: Issue: 2(L) - 12/05/16

Summary of Contents for SM3002DFD

Page 1: ... to remove the top of the compound rest from the compound rest bottom 3 2 Undo the handle screw of the graduated scale fig 2a and remove the spring clip and scale fig 2b Remove the compound rest screw retainer fig 2c retaining the fixing screws for future use and remove the compound rest feed screw 3 3 Remove the two large hex screws fig 3a retaining them for future use Remove the compound rest bo...

Page 2: ... the screw fits tightly and correctly into the slot on the feed screw 4 INSTALLATION 2 Installing the Cross Slide digital display 4 1 Remove the two socket head cap screws that retain the cross slide feed nut 4 2 Remove the cross slide feed nut fig 12a by turning the cross slide feed handle clockwise 4 3 Remove the cross slide feed handle fig 13a the spacer washer and the dial fig 13b fig 7 fig 8 ...

Page 3: ...ew Install the retaining screws provided do not overtighten 4 8 Install the spacer washer provided fig 18a and the cross slide rest feed handle 4 9 Fit the new cross slide feed nut fig 19a on the cross slide feed screw The screw holes in the nut must be facing upwards 4 10 Rotate the handle anticlockwise to draw the feed nut along the feed screw until the screw holes in the nut are aligned with th...

Page 4: ...th DO NOT use solvents or abrasives 6 2 Should the display begin to fade during use the batteries must be replaced Each display requires one LR44 battery 6 2 1 Remove the two screws fig 21a and the battery compartment cover fig 21b 6 2 2 Gently pull the yellow tag to eject the battery 6 2 3 Insert a new battery type LR44 into the battery compartment with the positive side facing up towards the LCD...

Reviews: