background image

INSTRUCTIONS FOR:

HALOGEN AUTO SECURITY LIGHT WITH 

CAMERA 300W/230V

MODEL No: 

SL300 

Thank you for purchasing a Sealey product. Manufactured to a 

high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

:  

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND 

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO 

MAY CAUSE DAMAGE, OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY.

  1.   SAFETY INSTRUCTIONS

 3. INSTALLATION

 2. INTRODUCTION

Original Language Version

SL300    Issue: 2 - 18/10/12

1.2.  GENERAL SAFETY. 

 

WARNING! Turn off the mains power supply before servicing or  

 

performing any maintenance.

 

Maintain the unit in good condition (Repairs must only be undertaken  

 

by a qualified electrician).

 

Only use genuine replacement halogen tubes (Sealey Part No.  

 ML300/01).

 

Ensure the unit is installed correctly in accordance with these   

instructions. 

 

Only install the unit on a vertical surface. 

DO NOT

 fix the unit on any  

 

horizontal surface  i.e. ceiling, or overhang.

 

Ideally the Installation should be away from flammable or combustible  

 

materials such as wood, cloth, paper etc.

    DANGER! DO NOT direct the light into a persons eyes. This unit  

 

has a very intensive light output, which if incorrectly used could  

 

cause eye damage.

 

DO NOT

 install the unit where it is likely to be knocked or hit.

 

DO NOT

 install in bathrooms, shower rooms, sauna or such locations.

 

DO NOT

 install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.

 

DO NOT

 touch the light when operating, allow to cool before touching,  

 

light operates at high temperature.

 

DO NOT

 use the light without the front glass shield. Avoid touching the  

 

glass shield as handling may reduce its serviceable life and cause the  

 

glass to crack.

 

DO NOT

 use the unit near flammable, combustible or explosive   

 

liquids, solids, gases or equipment.

1.1. ELECTRICAL.

 

 

WARNING!

 It is the user’s responsibility to read, understand and  

 

comply with the following:

 

You must check all electrical equipment and appliances to ensure they  

 

are safe before using. You must inspect power supply leads, plugs and  

 

all electrical connections for wear and damage. You must ensure the risk  

 

of electric shock is minimised by the installation of appropriate safety  

 

devices. An RCCB (Residual Current Circuit Breaker) should be  

 

incorporated in the main distribution board. 

You must

 also read and  

 

understand the following instructions concerning electrical safety: 

1.1.1.  Ensure the unit is connected to an appropriate electrical on/off switch. 

1.1.2.  Ensure the insulation on all cables and the product itself is safe before  

 

connecting to the mains power supply. 

1.1.3.  Ensure that cables are always protected against short circuit and  

 overload.

1.1.4.  Regularly inspect power supply, leads, plugs and all electrical  

 

connections for wear and damage, especially power connections, to  

 

ensure that none are loose. 

1.1.5. 

Important:

 

Ensure the voltage marked on the product is the same as  

 

the electrical power supply to be used.

1.1.6. 

DO NOT

 pull power cable once installed.

1.1.7. 

DO NOT

 pull power plugs from sockets by the power cable.

1.1.8. 

DO NOT

 use worn or damaged leads, plugs or connections.    

 

Immediately replace or have repaired by a qualified electrician. A UK 3  

 

pin plug with ASTA/BS approval is fitted. In case of damage, cut off and  

 

fit a new plug according to the following instructions (discard old plug  

 

safely). (UK only - see diagram below). 

a)  

Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) 

Connect the BROWN live wire to live terminal ‘L’.

c)  

Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) 

After wiring, check there are no bare wires, that all wires have been  

 

correctly connected and that the wire restraint is tight.

 

Double insulated products are fitted with live (BROWN) and neutral  

 

(BLUE) wires only. Double insulated products are always marked with  

 

this symbol      . To re-wire, connect the brown and blue wires as  

 

indicated above. 

DO NOT

 connect the brown or blue to the earth  

 terminal.

 

High powered floodlight with built in security camera, fitted with a 300W  

 

halogen tube. Features a 5 megapixel camera with PIR sensor for a  

 

crystal clear image. Unit can be adjusted to capture 3 or 9 burst pictures  

 

or video footage. Automatically starts capturing footage as soon as the  

 

PIR sensor is activated and is date and time stamped for easy  

 

distinction. All footage is stored via an on-board SD card (not supplied),  

 

which can be removed for easy viewing on laptop/computer. Features  

 

timing and capture setting controls allowing the user to easily adjust the  

 

delay between the picture bursts and adjusting the length of video  

 

capture. All settings are shown on LCD display. When SD card memory  

 

is full, the SL300 automatically cycles through and replaces old footage  

 

ensuring that you always have the most up to date recordings available.  

 

Unit is fitted with protective front cover designed to hide and protect  

 

controls and SD card. IP44 weatherproof design.

 

WARNING! DO NOT

 connect unit to the mains power supply  before  

 

installation. When properly installed, the SL300 can only then be  

 

connected to the mains.

3.1.   FITTING.

3.1.1.  Give careful consideration to the position of the unit to ensure you  

 

obtain maximum benefit from the lighting range, and that an appropriate  

 

electrical power source can be provided. 

3.1.2.  Mount the SL300 to a solid vertical surface more than ½" or 12.7mm  

 

thick in a secure location, overseeing the area to be monitored. Screws  

 

are provided with SL300 for installation.

3.1.3.  Mount the SL300 at least 2 metres above ground level with the camera  

 

pointing at a downward angle of 15°. Avoid mounting the SL300 facing  

 

to the East or to the West as the rising and setting of the sun may  

 

produce false triggers and over exposed images.

 

NOTE!

 It is recommended that EVA foam is installed between the wall  

 

mounting bracket (fig.2-10) and the wall to protect the unit. 

3.1.4.  Ensure the area in front of the SL300 is clear of any branches and other  

 

obstuctions that may obscure the PIR sensor.

© Jack Sealey Limited 

fig.1

RECOMMENDED FUSE RATING:

3AMP

Reviews: