Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

‰

  

WARNING!

 Turn off, or disconnect from air supply before servicing or performing any maintenance 

and when unit is not in use

.

 

‰

  

WARNING!

 This shot blasting kit will generate gritty dust which could damage surface finishes and contaminate moving parts. It is    

  recommended that shot blasting be carried out in a dedicated room free from unrelated materials, and where there is adequate lighting.

 

9

   Where this is not possible consideration should be given to covering exposed 

 

9

   surfaces and masking moving parts as necessary.  

 

‰

  

WARNING! 

Wear approved ear, eye, hand and respiratory protection when operating the blaster. A full range of personal safety equipment  

 is available from your Sealey stockist.

 

9

  Maintain correct balance and ensure firm footing by wearing non-slip shoes. 

 

9

   Spillages of abrasive material, which may be slippery, must be cleaned up immediately to avoid injury.

 

9

   Maintain the blaster in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   Keep the unit clean for best and safest performance. 

 

9

   Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.

 

9

   Always keep the blast nozzle directed at the workpiece.

 

9

   If a failure or malfunction occurs 

immediately disconnect from air supply.

 

9

   Keep all other persons away from the working area. Contact with high pressure blast or inhaling the dust generated is dangerous. If   

  other personnel are required in the vicinity of the shot blasting then they must wear protective equipment similar to the operator’s.

 

8

  

DO NOT 

use the blaster for any purpose other than that for which it is designed.

 

8

   DO NOT

 attempt to clear a blocked nozzle while the unit is pressurised.

 

8

   DO NOT

 allow untrained persons to operate the blaster.

 

8

 

  DO NOT

 leave the blaster operating unattended.

 

8

   DO NOT

 stand on the blaster.

 

8

   DO NOT 

direct air from the air hose at yourself or others.

 

8

   DO NOT 

operate system with air supply exceeding 120 psi.

 

8

 

  DO NOT

 operate the blaster if any parts are missing or damaged as this may cause failure and/or personal injury.

 

8

 

  DO NOT

 get the blaster wet or use in damp or wet locations or areas where there is condensation.

 

8

   DO  NOT

 operate the blaster when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

 

  DO NOT

 use any abrasive which contains free silica, as indicated in the Health & Safety Guidance Note EH59 (available from HMSO).

2.  INTRODUCTION

in

Suitable for use in the bodyshop. The feathering action makes this blaster ideal for treating stone chips. Supplied with a set of four rubber nozzles 

for sealing the gun head to the panel and a 700g bottle of blasting grit. Replacement nozzles are available.

3.  SPECIFICATION

Model no .....................................................................SG10E

Air consumption ........................................................ 5-10cfm

Operating pressure ................................................ 60-120psi

4.  AIR SUPPLY

 

‰

   WARNING!

 Ensure the air supply does not exceed 120psi

  

while operating the unit. Too high an air pressure will 

 

shorten the life of the unit due to excessive wear and may cause

 

damage and/or personal injury.

4.1. 

  

Ensure the gun trigger is in the ‘Off’ position before connecting to the air supply. 

4.2. 

  

Where possible the compressor should be sited in a separate room with the connecting airline kept as short as possible.  

4.3. 

  

The compressor should have an air filter and water separator (fig.1).

4.4. 

  

Drain the compressor air tank daily. Water in the air line will damage the unit.

4.5. 

  

The recommended hook-up procedure is shown in fig.1.

4.6. 

  

The minimum hose diameter should be 1/4” I.D. and fittings must have the same inside dimensions.           

4.7. 

  

Keep hoses away from heat, oil and sharp edges. Check hoses for wear and ensure that all connections are secure.