background image

INSTRUCTIONS FOR:

BENCH MOUNTED pillar Drill

MODEL No:

 

SDM30.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPORTANT:

 

plEaSE rEaD THESE iNSTrUCTiONS CarEFUllY. NOTE THE SaFE OpEraTiONal rEQUirEMENTS, WarNiNGS aND 

CaUTiONS. USE THiS prODUCT COrrECTlY aND WiTH CarE FOr THE pUrpOSE FOr WHiCH iT iS iNTENDED. FailUrE TO DO SO MaY 

CaUSE DaMaGE Or pErSONal iNJUrY aND Will iNValiDaTE THE WarraNTY. plEaSE KEEp iNSTrUCTiONS SaFE FOr FUTUrE USE.

  1.  SaFETY iNSTrUCTiONS

1.2 

GENEral SaFETY

 

WarNiNG! Disconnect drill from mains power before changing accessories, servicing or performing  

  any maintenance.

 

Maintain the

 

drill in good condition (use an authorised service agent).

 

WarNiNG!

 

Keep all guards and holding screws in place, tight and in good working order. Check  

 

  regularly for damaged parts. a guard, or any other part, that is damaged should be repaired/replaced  

  before the tool is used, to ensure that it will operate properly and perform its intended function. The  

  safety guard is a mandatory fitting where drill is used in premises covered by the Health & Safety at  

  Work act. 

 

  Check alignment of moving parts and check for possible broken parts. 

  Replace or repair damaged parts. 

Use recommended parts only. Non-authorised parts may be dangerous and  

  will invalidate the warranty.

  Ensure the set screws of the head frame are tight before using the drill. 

  Secure the drill to a supporting structure to avoid the machine tipping, sliding or walking. Drill is designed for  

  use with drill bits only. No other accessory may be used.

  Ensure the chuck is securely fastened to the spindle.

  Remove adjusting keys and wrenches from the machine and working area before switching on.

  Use clamps or a vice (not included) to secure the workpiece. Available from your Sealey dealer. DO NOT    

  secure the workpiece by hand. 

  Refer to speed chart for recommended drilling speeds.

 

WarNiNG! always wear approved eye or face protection when operating this drill. Use a face or dust  

  mask if dust is generated. 

 

WarNiNG! DO NOT wear gloves when drilling.

1.1. 

ElECTriCal SaFETY. 

 

WarNiNG! it is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and 

all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety 

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged 

into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by 

contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by 

 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those appliances 

 

and the safety of appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none  

 

is loose. 

1.1.6. 

Important: 

Ensure the voltage marked on the product is the same as the electrical power supply

 

to be used, and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may  

 

require a fuse smaller than 13 amps for certain products

 -

 see recommended fuse rating at right. 

1.1.7.  DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8.  DO NOT pull power plugs from sockets by the power cable.

1.1.9.  DO NOT use worn or damage leads, plugs or connections. Immediately replace or have  

 

 

repaired by a qualified electrician. Where a U.K. 3 pin plug with ASTA/BS approval is fit ed, in case of    

 

damage, cut off and fit a new plug according to the following instructions (discard old plug safely).

 

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

 

a)   Connect the gREEN/YEllOW earth wire to the earth terminal ‘E’.

 

b)  Connect the bROWN live wire to the live terminal ‘l’.

 

c)   Connect the bluE neutral wire to the neutral terminal ‘N’.

 

 

After wiring, check there are no bare wires, that all wires have been correctly  

 

 

 

connected, that the cable outer insulation extends past the cable restraint and that the  

 

 

restraint is tight.

 

 

Double insulated products are fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked   

 

with this symbol     . 

To re-wire, connect the brown & blue wires as indicated above.

 

DO NOT connect the brown or blue wires to  

 

the earth terminal.

1.1.10. 

NOTE: 

If a product requires more than a 13 amp electrical supply, then 

NO

 plug is fitted. 

You must

  then contact a qualified  

 

 

electrician to ensure a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and  

 

socket with your electrician. 

1.1.11. 

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

 

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores in the cable

 

is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the cable reel is suitable for this product and  

 

for others that may be used in the other output sockets, the use of 2.5mm² section is recommended .

blue 

Neutral 

wire

Yellow & green 

Earth wire 

Cable 

restraint

RECOMMENDED

FuSE RATINg

aMp

brown

live 

wire

Original Language Version

SDM30.V2    Issue: 1 - 30/06/11

Summary of Contents for SDM30.V2

Page 1: ...ions concerning electrical safety 1 1 1 The Electricity At Work Act 1989 requires all portable electrical appliances if used on business premises to be tested by a qualified electrician using a Portable Appliance Tester PAT at least once a year 1 1 2 The Health Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of app...

Page 2: ...or personal injury DO NOT leave the drill operating unattended DO NOT operate the drill when you are tired under the influence of alcohol drugs or intoxicating medication DO NOT pull the cable from the power supply When not in use switch the drill off remove plug from the power supply and do not leave until the tool has come to a complete stop 3 TECHNICAL SPECIFICATION 2 DESCRIPTION The SDM30 V2 v...

Page 3: ...ten lock nuts 6 6 3 When ready to drill simply pull the feed handle The drill feed will stop at the set depth 6 7 Guard 6 7 1 Always adjust guard length by loosening wing nut at each side fig 5 A to give maximum protection before starting to drill 6 OPERATING INSTRUCTIONS Note Figures are illustrative and may differ in detail from your drill 5 1 Assembly 5 1 1 Place the column assembly on the base...

Page 4: ... 3 Periodically lubricate all moving parts 8 MAINTENANCE 7 DRILL speeds Drill Speed rpm Drill Dia mm Steel Cast Iron Iron Alum Copper 3 1820 2580 2580 2580 4 5 1290 1350 1350 2580 6 970 1290 1290 2580 7 830 970 970 2580 8 830 970 970 2580 9 500 970 830 1820 10 500 830 830 1820 11 500 830 830 1820 12 420 830 500 1820 13 420 500 500 1350 14 420 500 500 1350 16 320 500 500 1290 18 320 420 420 1290 20...

Reviews: