Cleaning and user maintenance shall not be made by children without supervision.

2.  INTRODUCTION

 

Powerful dehumidification capacity, extracts up to 30 litres of water per day. Removes excess moisture from air, preventing build-up of mildew and 

mould. Features auto-defrost function, which activates if the room temperature falls too low. Washable activated carbon air filter. Refrigerant is 

environmentally friendly R290. May be connected to a drain hose for continuous operation. Mounted on castors for manoeuvrability.

3.  SPECIFICATION

4.  OPERATION

 

Efficiency of the dehumidifier is influenced by the air outside the room. For operating efficiency, try to avoid opening and closing the   

 

windows and doors. For best performance, operate the dehumidifier within the usable operating temperature. 

4.1. 

 

 OPERATION

4.1.1.   

Plug the unit in to the mains socket, a beep will be heard when inserting the plug.

4.1.2. 

  

Press the “ON/OFF” switch and the operation light will illuminate, the humidity display will light to display the previous set humidity. 

 

The initial setting for humidity is 60%, after 3 seconds the display will show the current humidity. 

4.1.3. 

  

Press the humidity up or down buttons to adjust to the desired humidity required.  If the required humidity is 3% below the current humidity  

 

the unit will start automatically, if the set humidity is 3% more than the current humidity the dehumidifier will automatically stop.

4.1.4. 

  

The unit has a memory function. Use the humidity up and down buttons to adjust to the

 desired setting and then press the memory  

 

button to record the setting, each time the machine is switched on it will automatically run at the required setting.

4.1.5.   

When setting the humidity to less than 30%, the unit will run continuously and the display will read “CO”.

4.1.6.   

To shut the dehumidifier down press the “ON/OFF” switch.  

 Note: 

If the humidity setting is greater than the current humidity the unit will not run.

 

‰

    WARNING!

 The fan motor and compressor must run for at least 3 minutes while dehumidifying. 

 

8

  

DO NOT

 start the dehumidifier immediately after shutting down, allow 3 minutes before restarting.

4.2. 

  

DEFROSTING 

 

   

4.2.1. 

  

The evaporator within the dehumidifier frosts during the dehumidifying operation at a room temperature of approximately 15°C or less.  

 

The defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes.  

 

The dehumidifying function will stop during the defrosting operation. Do not disconnect the plug or turn off the unit during the defrosting  

 operation.

 Note:

 This dehumidifier does not have a cooling function, it produces heat during the operation and room temperature will rise by 1°C to  

 

4°C. The temperature gets higher while it is operated in a closet, or similar. Furthermore, room temperature will rise because doors and  

 

windows are closed and heat is produced from other appliances in the room and from sun radiation.

4.3. 

 

 

EMPTYING THE WATER COLLECTION TANK

  

4.3.1. 

  

During the dehumidifying operation, water is collected in the water collection tank. When the tank is full of water, the dehumidifier stops 

 

operating automatically and the warning buzzer beeps twice. The unit will not restart until the water collection tank has been  

 

 emptied. 

4.3.2.   

Open the door and remove water collection tank from the dehumidifier by pulling it gently outwards by holding the sides of the tank    

 (fig.3).

fig.1

fig.2

Control Panel

Original Language Version

© Jack Sealey Limited

Model no.

SDH30.V2

Supply

230V ~ 50Hz

Power

M

ax/Rated - 710W/570W

Dehumidifying capacity

30L/Day 30°CRH80%

Freezing pressure (max)

2.5Mpa

Steaming pressure (max)

1.0MPa

Refrigerant

R

290/0.145kg

Global warming potential (rating)

3

M

ax. airflow

300m³/hr

W

orking temperature

5-32°C

W

orking space

78-104m³

S

DH30.V2 Issue 1 30/11/20

Summary of Contents for SDH30.V2

Page 1: ...utral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 Check that the dehumidifier is in sound condition and good working order Take immediate action to repair or replace damaged parts 9 Use recommended parts only Unauthorised parts may be da...

Page 2: ...e dehumidifier down press the ON OFF switch Note If the humidity setting is greater than the current humidity the unit will not run WARNING The fan motor and compressor must run for at least 3 minutes while dehumidifying 8 DO NOT start the dehumidifier immediately after shutting down allow 3 minutes before restarting 4 2 DEFROSTING 4 2 1 The evaporator within the dehumidifier frosts during the deh...

Page 3: ... bracket at the top of the door and then locate the lower section into the lower bracket 5 1 7 Close the door of the dehumidifier 5 2 STORAGE 5 2 1 Unplug the unit bundle the power cord and hang the bundled cord at the back of the unit 5 2 2 Remove the water collection tank and empty the water out of it Remove the tank cover and wash the inside of the tank with clean water The tank may be scratche...

Page 4: ... life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts withou...

Reviews: