background image

6.1.    

SET  UP

6.1.1.   

Select your cleaning solution, fill at least ½ of solution into the tank. 

DO NOT

 exceed the filling line.

 

   DANGER

DO NOT

 use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based  

 solvents.

6.1.2. 

  

Place the items into the basket, Slowly lower the basket into tank, 

DO NOT

 allow items to contact the tank bottom (solution should  

 

cover the items).

6.1.3. 

  

A: Plug the cleaner into (earthed) mains supply. 

 

B: Power on and turn on the power switch on back side of the machine. 

NOTE:

  After the power on, the temperature you see on the machine is environment temperature. Time and temperature default to those last  

 

used (3 minutes default time for initial use).

6.2.    

TIMER

6.2.1.   

Press                        to set the cleaning time. The timer will count down to 00:00, the tank will switch off. 

NOTE:

  Device’s with memory function will remember your last setting.

6.3.    

HEATING

6.3.1. 

  

Press               to start/stop heating. 

Press                           to set the temperature.

6.3.2. 

  

To get the best cleaning result, the solution’s temperature should be 40

°

 to 60

°

C. Warm water and dish washing liquid can soften   

 

grease and improve cleaning results.

6.3.3.   

When setting the temperature, if you want the temperature of the bath to be higher than the ambient temperature, press

                 

 

‘Heating’ button. The heating will come on. If your required temperature is below the ambient temperature, the heating will not come  

 

on. The light above the thermostat button will not illuminate.

6.3.4.   

Heating does shut off automatically, if timer is used, when it reaches zero

6.3.5. 

  

The device’s memory function will remember the last setting.

6.4.    

DEGAS  MODE

6.4.1. 

  

After setting the timer and temperature, press             , the light above this button will come on. The device will now be in degas mode:  

 

working for 6 seconds, and stopping for 2 seconds, then working for 6 seconds. It will cycle like this with the display counting down. 

6.4.2. 

  

Intermittent operation of ultrasonic power will degas the cleaning liquid.

6.4.3. 

  

If you want to transfer to another mode, press

             ‘normal’ or            ‘soft’. Then the ‘degas’ indicator will turn off and indicator  

 

button light for ‘normal’ or ‘soft’ turn on; to stop it working, press            ‘Degas’ again, then both heating and ultrasonic will stop and  

 

the corresponding indicator turn off.

6.5.    

NORMAL  MODE

6.5.1. 

  

After timer and temperature setting, press

             ‘Normal’ button, the corresponding button light will turn on and the device will work in  

 

‘normal mode’: continuously working with full ultrasonic power and countdown display.

6.5.2. 

  

To switch to other modes, press

            ‘Degas’ or            ‘soft’. To stop, press           ‘normal’ again, then both the heating and  

 

 

ultrasonic mode will stop and the corresponding button light will turn off.

6.6.    

SOFT  MODE

6.6.1. 

  

Set the timer and temperature, press

            , ‘soft mode’, the button light will turn on and the device will work in soft mode. To transfer  

 

to another mode, press

            ‘Degas’ or            ‘normal’, the ‘soft mode’ light will turn off and indicator light of ‘degas’ or ‘normal’ will  

 

turn on; To stop working, press           ‘soft’ again, then both heating and ultrasonic will stop and the corresponding button light will turn  

 

off.

NOTE:

  Degas, Normal and Soft cannot be operated simultaneously.

6.7.    

In the event of failure/emergency, disconnect the mains supply.

Control Panel

S

CT09 Issue 2(3) 12/03/19

Original Language Version

© Jack Sealey Limited

Summary of Contents for SCT09

Page 1: ...earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 8 8 DO NOT run the cleaner continuously for more than one hour at a time as do...

Page 2: ... 4 3 Optical During edging and polishing debris and abrasives can scratch lenses Ultrasonic cleaning can effectively protect the lenses 4 4 Regeneration For cleaning dot matrix printers and photocopier ink cartridges 4 5 Maintenance Bicycle gears air purifiers It cleans out debris in tiny holes and crevices effectively 5 PREPARATION 5 1 Carefully unpack the cleaner and remove all traces of packing...

Page 3: ...e device s memory function will remember the last setting 6 4 DEGAS MODE 6 4 1 After setting the timer and temperature press the light above this button will come on The device will now be in degas mode working for 6 seconds and stopping for 2 seconds then working for 6 seconds It will cycle like this with the display counting down 6 4 2 Intermittent operation of ultrasonic power will degas the cl...

Page 4: ...omes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in ...