6.1.
SET UP
6.1.1.
Select your cleaning solution, fill at least ½ of solution into the tank.
DO NOT
exceed the filling line.
▲
DANGER
!
DO NOT
use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based
solvents.
6.1.2.
Place the items into the basket, Slowly lower the basket into tank,
DO NOT
allow items to contact the tank bottom (solution should
cover the items).
6.1.3.
A: Plug the cleaner into (earthed) mains supply.
B: Power on and turn on the power switch on back side of the machine.
NOTE:
After the power on, the temperature you see on the machine is environment temperature. Time and temperature default to those last
used (3 minutes default time for initial use).
6.2.
TIMER
6.2.1.
Press to set the cleaning time. The timer will count down to 00:00, the tank will switch off.
NOTE:
Device’s with memory function will remember your last setting.
6.3.
HEATING
6.3.1.
Press to start/stop heating.
Press to set the temperature.
6.3.2.
To get the best cleaning result, the solution’s temperature should be 40
°
to 60
°
C. Warm water and dish washing liquid can soften
grease and improve cleaning results.
6.3.3.
When setting the temperature, if you want the temperature of the bath to be higher than the ambient temperature, press
‘Heating’ button. The heating will come on. If your required temperature is below the ambient temperature, the heating will not come
on. The light above the thermostat button will not illuminate.
6.3.4.
Heating does shut off automatically, if timer is used, when it reaches zero
6.3.5.
The device’s memory function will remember the last setting.
6.4.
DEGAS MODE
6.4.1.
After setting the timer and temperature, press , the light above this button will come on. The device will now be in degas mode:
working for 6 seconds, and stopping for 2 seconds, then working for 6 seconds. It will cycle like this with the display counting down.
6.4.2.
Intermittent operation of ultrasonic power will degas the cleaning liquid.
6.4.3.
If you want to transfer to another mode, press
‘normal’ or ‘soft’. Then the ‘degas’ indicator will turn off and indicator
button light for ‘normal’ or ‘soft’ turn on; to stop it working, press ‘Degas’ again, then both heating and ultrasonic will stop and
the corresponding indicator turn off.
6.5.
NORMAL MODE
6.5.1.
After timer and temperature setting, press
‘Normal’ button, the corresponding button light will turn on and the device will work in
‘normal mode’: continuously working with full ultrasonic power and countdown display.
6.5.2.
To switch to other modes, press
‘Degas’ or ‘soft’. To stop, press ‘normal’ again, then both the heating and
ultrasonic mode will stop and the corresponding button light will turn off.
6.6.
SOFT MODE
6.6.1.
Set the timer and temperature, press
, ‘soft mode’, the button light will turn on and the device will work in soft mode. To transfer
to another mode, press
‘Degas’ or ‘normal’, the ‘soft mode’ light will turn off and indicator light of ‘degas’ or ‘normal’ will
turn on; To stop working, press ‘soft’ again, then both heating and ultrasonic will stop and the corresponding button light will turn
off.
NOTE:
Degas, Normal and Soft cannot be operated simultaneously.
6.7.
In the event of failure/emergency, disconnect the mains supply.
Control Panel
S
CT09 Issue 2(3) 12/03/19
Original Language Version
© Jack Sealey Limited