6.  OPERATION

6.1.    

SET  UP

6.1.1.   

Select your cleaning solution and fill 2/3rds of the tank. 

DO NOT

 exceed the filling line. Be aware of the displacement volume of the  

 

objects being treated to avoid overspill. 

 

   DANGER

DO NOT

 use alcohol, gasoline or flammable solutions. Doing so could cause a fire or explosion. Use only water-based  

 solvents.

6.1.2. 

  

Place the items into the basket, Slowly lower the basket into tank. 

DO NOT

 allow items to contact the tank bottom and always use the  

 

basket to immerse items. The solution should cover the items - see section 6.1.1.

6.1.3. 

  

A: Plug the cleaner into (earthed) mains supply. 

 

B: Turn mains supply on and turn on the power switch on rear side of the machine. 

NOTE:

  After turning power on, initially the temperature you see on the display is the ambient temperature. Timing and temperature settings  

 

default to those last used after 3 seconds.

6.2.    

TIMER

6.2.1.   

Press                        to set the cleaning time. The timer will count down to 00:00, the tank will switch off.

NOTE:

  Devices with memory function will remember your last setting.

6.3.    

HEATING

6.3.1. 

  

Press               to start/stop heating. 

Press                           to set the temperature.

6.3.2. 

  

To get the best cleaning result, the solution’s temperature should be 40

°

 to 60

°

C. Warm water and dish washing liquid can soften   

 

grease and improve cleaning results.

6.3.3.   

When setting the temperature, if you want the temperature of the bath to be higher than the ambient temperature, press

                 

 

‘Heating’ button. The heating will come on. If your required temperature is below the ambient temperature, the heating will not come  

 

on. The light above the thermostat button will not illuminate.

6.3.4.   

Heating does shut off automatically, if timer is used, when it reaches zero

.

6.3.5. 

  

The device’s memory function will remember the last setting.

6.4.    

DEGAS  MODE

6.4.1. 

  

After setting the timer and temperature, press             , the light above this button will come on. The device will now be in degas mode:  

 

working for 6 seconds, and stopping for 2 seconds, then working for 6 seconds. It will cycle like this with the display counting down. 

6.4.2. 

  

Intermittent operation of ultrasonic power will degas the cleaning liquid.

6.4.3. 

  

If you want to transfer to another mode, press

             ‘normal’ or            ‘soft’. Then the ‘degas’ indicator will turn off and indicator  

 

button light for ‘normal’ or ‘soft’ turn on; to stop it working, press            ‘Degas’ again, then both heating and ultrasonic will stop and  

 

the corresponding indicator turn off.

6.5.    

NORMAL  MODE

6.5.1. 

  

After timer and temperature setting, press

             ‘Normal’ button, the corresponding button light will turn on and the device will work in  

 

‘normal mode’: continuously working with full ultrasonic power and countdown display.

6.5.2. 

  

To switch to other modes, press

            ‘Degas’ or            ‘soft’. To stop, press           ‘normal’ again, then both the heating and  

 

 

ultrasonic mode will stop and the corresponding button light will turn off.

6.6.    

SOFT  MODE

6.6.1. 

  

Set the timer and temperature, press

            , ‘soft mode’, the button light will turn on and the device will work in soft mode. To transfer  

 

to another mode, press

            ‘Degas’ or            ‘normal’, the ‘soft mode’ light will turn off and indicator light of ‘degas’ or ‘normal’ will  

 

turn on; To stop working, press           ‘soft’ again, then both heating and ultrasonic will stop and the corresponding button light will turn  

 

off.

NOTE:

  Degas, Normal and Soft cannot be operated simultaneously.

Control Panel

S

CT03, SCT09, SCT27  Issue1 25/09/20

Summary of Contents for SCT03

Page 1: ... earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 8 DO NOT run the cleaner continuously for more than one hou...

Page 2: ...cartridges 4 5 MAINTENANCE Bicycle gears air purifiers It cleans out debris in tiny holes and crevices effectively 5 PREPARATION 5 1 Carefully unpack the cleaner and remove all traces of packing materials from it Visually inspect the cleaner for any parts that may have become loose or damaged during transit 5 2 Place the cleaner on a flat clean surface where the cooling fans will receive adequate ...

Page 3: ... come on The light above the thermostat button will not illuminate 6 3 4 Heating does shut off automatically if timer is used when it reaches zero 6 3 5 The device s memory function will remember the last setting 6 4 DEGAS MODE 6 4 1 After setting the timer and temperature press the light above this button will come on The device will now be in degas mode working for 6 seconds and stopping for 2 s...

Page 4: ...ortant No Liability is accepted for incorrect use of this product Warranty Guarantee is 12 months from purchase date proof of which is required for any claim WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally ...

Reviews: