4. OPERATION

CONTENTS  / MAIN FEATURES (See fig.1)

1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control panel
2 . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal louvres
3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical louvres 
4. . . . . . . . . . . . . . . . . . . . . . . . . Water level indicator
5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Castor
6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handle

8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drawer
9 . . . . . . . . . . . . . . . . . . . . . . . . Top water tank cover
10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter
11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable tidies 
13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mains lead 
14 . . . . . . . . . . . . . . . . . . . . . . . . . . Drainage stopper
15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ice pack

Fig.2

4.2

CONTROL PANEL FUNCTIONS.

4.2.1 

Warm/Cool Air flow Control Lever.

Before the heater functions can be used this lever must be pushed up to 

the ‘WARM’ position. When the cooling functions are required move the lever to the lower ‘COOL’ position.

4.2.2 

Timer.

By repeatedly pressing the timer button the timer can be set to switch off the unit in periods of time from 

from 0.5 to 7.5 hours in half hour increments.  As you press the button the four indicator lights above it will 
illuminate in different combinations. The time period chosen is indicated by adding together the time values 
above each illuminated light. To turn off the timer, advance the time setting to 7.5 hours ( all four lights on ) then 
press the button once more at which point all four lights will go off.

4.2.3

Wind.

The direction of the air flow coming out of the unit is controlled by two sets of louvres. The horizontal 

louvres on the front of the machine can be adjusted up or down manually. Behind these louvres is a second set 
of electrically driven vertical louvres which can be made to swing from side to side by pressing the ‘Wind’ button.
An indicator light will come on above the button to show that the louvres are active. To cancel the movement 
press the button again. The indicator light will go out.

4.2.4

Speed.

There are three indicator lights above the button which show the three speeds available, High, Medium, 

Low.  By repeatedly pressing the button you can cycle through the three speeds. Stop when you reach the 
desired speed.

4.2.5

Warm.

This unit contains a special heater known as a Positive Temperature Coefficient element. Repeatedly 

press the button to cycle through the available heating options. The first press will illuminate the PTC1 indicator 
which is equivalent to 1000Watts. The second press will illuminate both PTC1 and PTC2 indicators which is 
equivalent to 2000Watts. A third press switches the heater off and both lights go out. This button and it’s 
indicators will not work unless the air flow control lever is set at ‘WARM’.

4.2.6

Cool.

Before switching to the cooling function make sure that the air flow control lever is moved downwards to 

the ‘COOL’ position. Press the button once to activate the cooling function. The ‘Icy Breeze’ indicator lamp above
the button will illuminate. To stop the cooling function press the button again and the indicator light will go out.

4.2.7 

ON/OFF.

When the unit is plugged in it will beep to show that it is live. Switch the unit on by pressing the 

ON/OFF button. The power indicator above the button will illuminate.

4.1 Product description.

The SAC41 is a multifunction 4-in-1 unit comprising air cooler, heater, humidifier and air 

purifier. It features a 3-speed fan, adjustable airflow direction and timer. Refrigerant-free cooling is achieved by 
evaporating water, which can be enhanced by adding ice to the built-in ice compartment or ice packs to the 
built-in draw. The unit has a fan-assisted heating function with two settings. Air purification is achieved by 
negative ion generation and an activated carbon filter. The unit is supplied with an electronic remote control and is
mounted on castors for manoeuvrability.

SAC41 - 1 - 05/12/06

Summary of Contents for SAC41

Page 1: ...cting it to the power supply See 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and th...

Page 2: ...ctric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any wet or damp environments of high condensation DO NOT use the unit out of doors This unit is designed for indo...

Page 3: ...hree speeds available High Medium Low By repeatedly pressing the button you can cycle through the three speeds Stop when you reach the desired speed 4 2 5 Warm This unit contains a special heater known as a Positive Temperature Coefficient element Repeatedly press the button to cycle through the available heating options The first press will illuminate the PTC1 indicator which is equivalent to 100...

Page 4: ...g is drawn into the unit through an activated carbon filter and thus cleans the air of dust and other particles 4 7 2 The unit also contains a negative ion generator known to produce cleaner fresher air and reduce airborne odours The ion generator starts to work as soon as the unit is switched on and works in both heating and cooling modes 4 8 USING THE UNIT AS A FAN ONLY 4 8 1 If neither heating ...

Page 5: ...unit on a regular basis and replace or repair any damaged parts Use recommended parts and an authorised service agent Unauthorised parts may be dangerous and will invalidate the warranty 5 1 2 Do not use any solvents or abrasive material to clean the plastic exterior of the unit Use only a damp soft cloth for cleaning and dry the unit afterwards with a clean dry soft cloth 5 2 Air Filter Clean the...

Page 6: ...upon request to Jack Sealey Ltd For Jack Sealey Ltd Sole importer into the UK of Sealey Power Products Air Cooler Air Purifier Humidifier Heater Unit Model No SAC41 72 23 EEC Low Voltage Directive 89 336 EEC EMC Directive 93 68 EEC Marking Directive 2002 95 EC RoHS Directive 2002 96 EC WEEE Directive 24th November 2006 Signed by Steve Buckle SAC41 1 05 12 06 Environmental Protection Recycle unwant...

Page 7: ... 15 LOWER WATER TANK COVER 16 SAC41 16 WATER TANK LOWER 17 SAC41 17 FAN 18 SAC41 18 CAPACITOR ITEM PART NO DESCRIPTION 19 SAC41 19 RIGHT HAND SIDE CASING 20 SAC41 20 CLIP FOR POWER CORD 21 SAC41 21 IMPOSE LINE CAP 22 SAC41 22 MOTOR 25 SAC41 25 ANION 26 SAC41 26 TERMINAL BLOCKS 27 SAC41 27 AXLE FOR WATER CURTAIN 28 SAC41 28 MOTOR FOR WATER CURTAIN 29 SAC41 29 FILTER 30 SAC41 30 WATER CURTAIN 31 SAC...

Reviews: