 2.  SPECIFICATION

 3.  OPERATION

Motor Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V

Cooler:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70W

Heater: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000W/2000W

Anion Density:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 million/cm³

Maximum Air Flow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350mtr³/hr

Cooling Water Tank:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.0ltr

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.5kg

fig.1

Original Language Version

SAC41.V2    Issue: 2(L) - 31/12/13

3.1.  CONTROL PANEL FUNCTIONS.

3.1.1. 

Heat/Cool Air Selection Control (on side of unit - fig.1)

 

Before the heater functions can be used this lever must be moved to the HEAT position. When the cooling functions are required move  

 

the lever to the COOL position.

3.1.2.  

Timer

 

 

By pressing the timer button, the timer can be set to switch off the unit, in periods of time from 0.5 to 7.5 hours in half hour increments. As you  

 

press the button the four indicator lights above it will illuminate in different combinations. The time period selected is indicated by adding

 

together the time values above each illuminated light. To turn the timer off, advance the timer setting to 7.5 hours (all four lights illuminated),  

 

then press the button once more and the timer is switched off.

 

NOTE: If the timer is not selected, the unit will continue to work in the mode that it is set, until the unit is switched off manually.

3.1.3. 

Wind

 

The direction of the air flow coming out of the unit is controlled by two sets of louvres. The horizontal louvres on the front of the  

 

 

machine can be manually adjusted up or down. Behind these louvres is a second set of electrically driven vertical louvres which can be  

 

made to oscillate from side to side by pressing the Wind button. An indicator light will illuminate above the button to show that the louvres are  

 

working. To cancel the movement, press the button again. The indicator light will go out.

3.1.4. 

Speed

 

There are three speeds available: High, Medium, Low. Press the button to cycle through these until the desired speed is reached.

 

NOTE: In Heat mode, only two fan speeds are available: Medium and Low.

3.1.5. 

Heat

 

Before switching to the Heat function, make sure that the air flow control lever is moved to the HEAT position. This unit contains a special  

 

heater with a Positive Temperature Coefficient element. Press the button to cycle through the available heating options. One press will 

 

illuminate the PTC1 indicator which is equivalent to 1000Watts. A second press will illuminate both PTC1 and PTC2 indicators, which is

 

equivalent to 2000Watts. A third press switches the heater off. 

3.1.6. 

Cool

 

Before switching to the cooling function make sure that the air flow control lever is moved to the COOL position. Press the button once to

 

activate the cooling function. The ‘Icy Breeze’ indicator light above the button will illuminate. To stop the cooling function, press the button  

 

again and the indicator light will go out.

3.1.7.  

On/Off

 

When the unit is plugged in, it will beep to show that it is in Standby mode. Switch the unit on by pressing the ON/OFF button. The power 

 

indicator above the button will illuminate.

Multifunction 4-in-1 unit comprising Air Cooler, Heater, Humidifier and Air Purifier. Features a 3-speed fan, adjustable airflow direction and    

timer. Refrigerant-free cooling is achieved by evaporating water, which can be enhanced by adding ice. Fan-assisted heating function with two

settings. Air purification is achieved by negative ion generation and an activated carbon filter. Supplied with electronic remote control. Mounted  

on castors for manoeuvrability.

© Jack Sealey Limited

Summary of Contents for SAC41.V2

Page 1: ... protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity at Work Act 1989 requires that all portable electrical appliances if used on business premises are tested by a qualified electrician using a Por...

Page 2: ...ancel the movement press the button again The indicator light will go out 3 1 4 Speed There are three speeds available High Medium Low Press the button to cycle through these until the desired speed is reached NOTE In Heat mode only two fan speeds are available Medium and Low 3 1 5 Heat Before switching to the Heat function make sure that the air flow control lever is moved to the HEAT position Th...

Page 3: ... Only two fan speeds are available Medium and Low 3 4 4 Activate the louvre side oscillation if required using the WIND button Adjust the air flow up or down manually via the horizontal louvres 3 4 5 Set the timer if required using the TIMER button 3 4 6 To stop the heating function press the HEAT button until the indicator lights go out 3 4 7 When the unit is switched OFF using the ON OFF button ...

Page 4: ... General Maintenance Turn the unit OFF and disconnect it from the mains power supply before cleaning or performing any maintenance 4 1 1 Inspect the unit on a regular basis and replace or repair any damaged parts Use recommended parts and an authorised service agent Unauthorised parts may be dangerous and will invalidate the warranty 4 1 2 Do not use any solvents or abrasive material to clean the ...

Reviews: