background image

Compressor 24ltr DireCt Drive 2hp/
4 pC Air ACCessorY Kit 

model no: 

sAC2420A/sAC2420ApK

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  sAfetY

1.1.     eleCtriCAl  sAfetY

 

‰

  

WArNiNG!

 It is the user’s responsibility to check the following:

  Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply    

 

 

  leads, plugs and all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device)  

  is used with all electrical products. You may obtain an RCd by contacting your local Sealey stockist. 

  If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

  Appliance Test) tested.

 

eleCtriCAl sAfetY iNformAtioN it is important that the following information is read and understood.

1.1.1.    ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.    Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

   importANt:

 Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

  correct fuse - see fuse rating in these instructions.

 

8

   Do  Not

 pull or carry the appliance by the power cable.

 

8

  

Do Not

 pull the plug from the socket by the cable. 

 

8

   Do  Not

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by  

 a qualified electrician.

1.1.4. 

   This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

      

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

      

Ensure that repairs are carried out by a qualified electrician.

          Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

  A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

  B) Connect the BROWN live wire to the live terminal ‘L’.

  C) Connect the BLUE neutral wire to the neutral terminal ‘N’.

      

ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

         Sealey recommend that repairs are carried out by a qualified electrician.

 

importANt!

 The use of extension leads to connect these compressors to the mains is not recommended  

 

as the resulting voltage drop reduces motor, and therefore pump performance.

1.2.     GeNerAl sAfetY

 

 

9

  

Familiarise yourself with the application and limitations of the compressor.   

 

 

9

  

ensure the compressor is in good order and condition before use. If in any doubt 

Do Not 

use the unit  

 and contact an electrician/service agent.

 

‰

  WArNiNG! Compressor must only be serviced by an authorised agent. Do Not tamper with, or attempt to adjust, pressure    

 switch or safety valve.

 

9

  

Before moving, or maintaining the compressor, ensure it is unplugged from the mains supply and that the air/tank pressure has been  

 

 vented. 

 

9

  

Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. 

Unauthorised parts may    

 be dangerous and will invalidate your warranty.

 

9

  Read the instructions relating to any accessory to be used with this compressor. ensure the safe working pressure of any air appliance  

 used exceeds compressors output pressure. If using a spray gun, check that the area selected for spraying is provided with an air  

 

 change/ventilation system.

 

9

  ensure the air supply valve is turned off before disconnecting the air supply hose.

 

9

  To move the compressor, use the handle only. maintain unit’s centre of gravity when lifting. 

Do Not

 attempt to lift or move the  

 

 compressor by any other means. 

 

9

 

Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

 

Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

 

9

 

ensure the air hose is not tangled, twisted or pinched.

 

9

  

Keep children and unauthorised persons away from the working area.

 

8

  

Do Not

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

  

Do Not

 carry out any welding operations on any pressurised parts of the vessel.

 

8

  

Do Not

 use the compressor outdoors, or in damp, or wet, locations.

 

8

  

Do Not

 operate within the vicinity of flammable liquids, gases or solids.

SAC2420A, SAC2420APK

 | Issue 1 12/06/19

Original Language Version

© Jack Sealey limited

Refer to 

instructions

Wear eye 

protection

Wear ear 

protection

ensure oil level 

is correct before 

first use

WArNiNG:

High Voltage

WArNiNG:

Hot surface

WArNiNG:

Automatic 

start up

Indoor use only

Do Not

 open 

the air cock 

before an air 

hose is attached

replacement fuse 

rating:

Summary of Contents for SAC2420A

Page 1: ... to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician IMPORTANT The use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance 1 2 GENERAL SAFETY 9 9 Fa...

Page 2: ...lly see fig 2 and should be in a position that allows good air circulation around the unit 4 4 The compressor is supplied without oil in it The oil is in a separate container Remove the transit plug from the oil filler aperture pour oil into the aperture until it has reached the correct level on the sight fig 3 Fit the oil filler breather supplied into the aperture 4 5 Ensure that the air vent in ...

Page 3: ...der to keep the compressor in good working condition periodical maintenance is essential 6 1 After the first 50 working hours replace the lubricating oil see Item 6 3 6 2 Operations to be carried out daily 6 2 1 Drain condensation place a container under the valve and open the valve by turning anti clockwise fig 1 Retighten the valve 6 2 2 Check that all nuts and bolts are tight particularly those...

Page 4: ...nt Compressor stops and will not restart Motor failure Contact Authorised Service Agent Compressor does not stop at maximum pressure 1 Pressure switch fault 2 Filter clogged 3 Head gasket or valve fault 1 Contact Authorised Service Agent 2 Replace filter element 3 Contact Authorised Service Agent Compressor noisy with metallic knock Bearing or piston damage Contact Authorised Service Agent Excessi...

Page 5: ...ng Ensure the floor is not slippery and wear non slip shoes 9 9 Remove ill fitting clothes ties watches rings other loose jewellery and contain tie back long hair 9 9 Keep children and unauthorised persons away from the working area 9 9 Secure non stable work piece with a clamp vice or other adequate holding device 9 9 Avoid unintentional starting WARNING air pressure should not exceed 90psi 9 9 K...

Page 6: ...rom the air supply before attempting any cleaning or maintenance 15 1 Cleaning the gun 15 1 1 Flush the gun through with clean solvent 15 1 2 Use a bristle brush and solvent to wash off accumulated paint 15 1 3 Clean the air nozzle using a brush Blow clean with air Handle all nozzles carefully and do not make any alterations in the gun 15 1 4 Wipe the outside of the gun with a dampened solvent rag...

Page 7: ... be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Weee Regulations Dispose of this product at the end of its working life in compliance with the ...

Reviews: