background image

 BELT DRIVE COMPRESSOR 3HP

MODEL NO’S: 

SAC20030B (200L), SAC15030B (150L)

 

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1.    

ELECTRICAL  SAFETY

 

‰

   WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check 

 

all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors  

 

for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. 

 

A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual  

 

Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is 

 

not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your  

 

Sealey dealer. You must also read and understand the following instructions concerning electrical safety.

1.1.1.   

The 

Electricity at Work Act 1989

 requires that all portable electrical appliances, if used on business premises, are tested  

 

 

by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.   

The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those   

 

 

appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and use a    

 

Portable Appliance Tester.

1.1.4.   

Ensure that cables are always protected against short circuit  and overload.

1.1.5.   

Regularly inspect power supply cables and plugs for wear or  damage and check all connections to ensure 

 

that none is loose.

1.1.6.   

IMPORTANT: 

Ensure that the voltage marked on the appliance matches the power supply to be used and 

 

that the plug is fitted with the correct fuse - see fuse rating at right.

 

8

  

DO NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable.

 

8

  

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or 

 

replaced by a qualified electrician.

1.1.7. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

        

 Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

 a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

 b) Connect the BROWN live wire to the live terminal ‘L’.

 

 c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

 Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

 IMPORTANT!

  The use of extension leads to connect these compressors to the mains is not recommended as the resulting  

 

 

voltage drop reduces motor, and therefore pump performance.

Original Language Version

© Jack Sealey Limited

Refer to 

instruction

manual

Warning: Hot 

surface

Warning: 

Electricity

Warning:

Automatic 

startup

Wear ear 

protection

Replacement fuse 

rating:

 

13 AMP

SAC20030B, SAC15030B       Issue: 1     08/03/21

Summary of Contents for SAC20030B

Page 1: ...or the safe condition of those appliances and the safety of the appliance operators If in any doubt about electrical safety contact a qualified electrician 1 1 3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply See 1 1 1 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload ...

Page 2: ...T operate the compressor without an air filter 8 DO NOT allow anyone to operate the compressor unless they have received full instructions WARNING The air tank is a pressure vessel and the following safety measures apply 8 DO NOT tamper with the safety valve DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank 8 DO NOT subject the tank to impact vibration or to heat and...

Page 3: ...RATION WARNING Ensure that you have read understood and apply Section 1 safety instructions IMPORTANT Use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance and could damage the compressor NOTE Take care when selecting tools for use with the compressor Air tool manufacturers normally express the...

Page 4: ...r disconnect from electricity supply and release all air from the tank 6 2 Operations to be carried out after the first 50 working hours a Check that all bolts nuts are tight particularly those retaining the crankcase and cylinder head b Replace the lubricating oil fig 4 6 3 Operations to be carried out weekly a Drain condensation by opening the valve located under the tank fig 7 Place a container...

Page 5: ... and look for bubbles Tighten connections showing leaks If problem persists contact Authorised Service Agent Pressure switch valve leaks when compressor is idle Non return valve seal defective Discharge all tank pressure Referring to fig 4 and fig 9 unscrew valve cap A Clean rubber disc B and its seat Refit all parts accurately Compressor stops and does not restart Power failure Motor failure Chec...

Page 6: ...rding to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is accepted for incorrect use of this product Warranty Guarantee is 12 months from purchase date proof of which is required for any claim WEEE REGULATIONS Dispose of this product at the end of ...

Reviews: