![Sealey SAC1903B Instructions Download Page 4](http://html.mh-extra.com/html/sealey/sac1903b/sac1903b_instructions_1224053004.webp)
5.6.
RECOMMENDED OILS
synthetic oil suitable for temperatures ranging from -5°c to 45°c:
viscosity 5W50. We do not recommend using mineral oil in these
compressors.
Part no. Qty. description.
fso1 1ltr x 12 compressor oil fully synthetic
fso1s 1ltr x 1 compressor oil fully synthetic
fso5 5ltr x 1 compressor oil fully synthetic
5.7.
IMPORTANT WARNING
- Air contaminants taken into the
compressor will affect optimum performance. example: Body
filler dust or paint overspray will clog the pump intake filter and
may cause internal damage to pump/motor components. Please
note that any parts damaged by any type of contamination will
not be covered by warranty.
fig.6
6. TROUBLE SHOOTING
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
no liability is accepted for incorrect use of this product.
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION:
for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park
,
Bury st. edmunds, suffolk,
IP32 7Ar
www.sealey.co.uk
Web
fig.5
fig.7
fig.8
Fault
Cause
Remedy
Pressure drop in the
tank.
Air leaks at
connections.
run compressor to max.
pressure, switch off.
Brush soap solution over
connections and look for
bubbles. tighten connections
showing leaks. If problem
persists contact Authorised
service Agent.
Pressure switch
valve leaks when
compressor is idle.
non-return valve seal
defective.
discharge all tank pressure.
referring to fig.8, unscrew
valve cap 'A'. clean rubber
disc 'B' and its seat. refit all
parts accurately.
compressor stops
and does not restart.
Power failure.
Motor failure.
check electricity supply and
fuse.
contact Authorised service
Agent.
compressor does
not stop at max
pressure.
Pressure switch fault.
contact Authorised service
Agent.
compressor does
not reach max
pressure.
filter clogged.
Head gasket or valve
fault.
replace filter element.
contact Authorised service
Agent.
compressor noisy
with metallic knock.
low oil level.
Bearing or piston
damage.
turn off and top up oil
immediately.
contact Authorised service
Agent.
Original Language Version
sAc1903B Issue: 2 - 21/02/12
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to
www.sealey.co.uk, email [email protected] or phone 01284 757500.
Maintenance Operations
Weekly 50hrs
100hrs
400 hrs
drain condensation
•
check oil level
•
clean intake filter
•
check for oil leaks
•
replace oil
•
check cut-out
•
General cleaning of
compressor
•
replace air filter
•
check tube fittings and
electrical connections
•
Internal & external
inspection of tank
•
Summary of Contents for SAC1903B