  2.  INTRODUCTION

  3.  SPECIFICATION

  4.  INSTALLATION

Original Language Version

©

 Jack Sealey Limited

Thermostatically controlled unit with extendable exhaust hose and window kit - ideal for home or office environments. Features three-speed fan and 

electronic remote control. Air conditioning temperature range 18-30°C. Also features heating and dehumidifying functions. Dehumidifier capable of 

removing up to 33.6ltr/day. Refrigerant is R410A. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in use.

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAC12000

Cooling Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12000Btu/hr

Supply: 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

230V

Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1355W

Maximum Airflow:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

435m

³

/hr

Maximum Water Extraction Rate:

. . . . . . . . . . . . . . . . . . .

33.6ltr/day

Refrigerant:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

R410A

Discharge Side Pressure:

. . . . . . . . . . . . . . . . . . . . . . . . . . .

3.5Mpa

Suction Side Pressure;

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1MPa

Exhaust Hose Length:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500mm

Energy Class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.5kg

fig.1

1:  Front Cover

2:  Control Panel

3:  Top Cover

4:  Air Outlet Grille

5:  Carrying Handle

6:  Remote Control

7:  Upper Filter Frame

8:  Exhaust Air Outlet

9:  Lower Filter Frame

10:Drain 

11:Power Cable Stowage  

12:Plug Stowage

13:Hose Adaptor (2 halves)

14:Exhaust Hose

15:Window Adaptor

4.1. 

IMPORTANT:

 Allow the refrigerant to settle for at least two hours before using the unit.

4.2. 

Exhaust Hose Assembly

4.2.1.

 

Snap the two halves of the hose adaptor (fig.1.13) together (do not use excessive force).

4.2.2.  Pull one end exhaust hose (fig1.14) out from its closed position.

4.2.3.  Insert the end into the exhaust air outlet (fig.1.8) and turn in an anticlockwise direction until tight.

4.2.4.  Pull the free end out and screw the assembled hose adaptor onto the outer end of the exhaust hose in an anticlockwise direction until    

 tight.

4.3. 

Window Adaptor

4.3.1.  Slide the window adaptor to the correct width for the window opening and locate the stop screw in the relevant screw hole to stop the slide 

 closing.

4.3.2.  Close the window onto the window adaptor, clamping it in place. This can be achieved with sash windows, sliding windows or vertically hinged  

 widows.

4.3.3.  Insert the hose adaptor into the window adaptor (figs 2 and 3).

4.4. 

DO NOT

 use an extension hose or hose different from the one

 

supplied. The length and diameter of the hose supplied are the

 

optimum size for this unit. Changing those dimensions could 

 

affect the performance.

4.5.

 

Location

 

The SAC12000 should be located on a flat floor and be 500mm clear of any surrounding objects.

fig.2

fig.3

SAC120000   Issue: 1- 16/01/15

NOTE: 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack  

                          of  experience  and  knowledge  if  they  have  been  given  supervision  or  instruction  concerning  use  of  the  appliance  in  a  safe  way  and  understand                                                      

             the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without 

             supervision.

Summary of Contents for SAC12000

Page 1: ...aint is tight Double insulated products are marked with the Class II symbol Class II products are wired with live brown and neutral blue only To rewire connect the wires as indicated in diagram DO NOT connect either wire to the earth terminal 1 3 Products which require more than 13 amps are supplied without a plug Contact a qualified electrician to ensure that a suitably rated supply is available ...

Page 2: ...nd exhaust hose fig1 14 out from its closed position 4 2 3 Insert the end into the exhaust air outlet fig 1 8 and turn in an anticlockwise direction until tight 4 2 4 Pull the free end out and screw the assembled hose adaptor onto the outer end of the exhaust hose in an anticlockwise direction until tight 4 3 Window Adaptor 4 3 1 Slide the window adaptor to the correct width for the window opening...

Page 3: ...ng the batteries in the compartment Ensure that the correct polarity of the batteries 5 2 2 The icons on the remote control are identical to those on the control panel as described in section 5 1 above and fulfil the same functions The only difference is the Temperature C F button which allows the temperature scale to be altered 5 2 3 The key pad can be locked by pressing a sharp object into the L...

Page 4: ...to clean the plastic exterior of the unit Use only a damp soft cloth for cleaning and dry the unit afterwards with a clean dry soft cloth 6 2 Air Filters Clean the air filters every two weeks for optimum performance The filters are situated at the rear of the unit figs 8 and 9 and are held in place by plastic frames 6 2 1 Upper Filter Pull the top handle gently to release the holding lugs and remo...

Reviews: