![Sealey SAC12000.V4 Instructions Download Page 5](http://html.mh-extra.com/html/sealey/sac12000-v4/sac12000-v4_instructions_1224094005.webp)
8. TROUBLE SHOOTING
Original Language Version
© Jack Sealey Limited
Symptom
Inspection
Solution
The unit is not
working
Check the mains supply
Insert the power cord securely into the wall outlet
Check if the water level indicator lights
up?
Empty the drain pan. See Section 5.10
Check the room temperature.
The range of operating temperature is 5-35
o
C
The unit works with
reduced capacity
Check if the air duct is blocked
Clear the obstacle.
C
heck the air filter for dirt
C
lean the air filter. See Section 7
Check if the room door or window is open.
Keep the door and windows closed.
Check if the desired operating mode is
selected and temperature is properly set.
Set the mode and temperature at proper set-point
See Section 5
The exhaust hose is detached.
Make sure the exhaust hose is securely attached.
W
ater Leakage
O
verflow while moving the unit.
Empty the water tank before transport.
Check if the drain hose is kinked or bent.
Straighten the hose to avoid a trap existing.
Excessive Noise
Check if the unit is securely positioned.
P
lace the unit on horizontal and firm ground.
Check if any loose, vibrating parts.
Secure and tighten the parts.
N
oise sounds like water flowing.
N
oise comes from flowing refrigerant. This is normal.
Error
Codes
E0
C
ommunication faults between main PCB
and display PCB.
C
heck the wire harness of the display PCB for damage.
E1
Ambient temperature sensor failure
Check connection or replace it. To clean or replace the
temperature sensor.
E2
Coil temperature sensor failures.
Check connection or replace it. To clean or replace the
temperature sensor.
Ft
Condensate water high level alarm.
Empty the drain pan. See Section 5.10
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on [email protected] or 01284 757505.
Important
: No Liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
S
AC12000.V4 Issue 2 (3) 16/06/22