background image

8.  TROUBLE SHOOTING

Original Language Version

© Jack Sealey Limited

Symptom

Inspection

Solution 

The unit is not 
working

Check the mains supply

Insert the power cord securely into the wall outlet

Check if the water level indicator lights 
up?

Empty the drain pan. See Section 5.10

Check the room temperature.

The range of operating temperature is 5-35

o

C

The unit works with 
reduced capacity

Check if the air duct is blocked

Clear the obstacle.

C

heck the air filter for dirt

C

lean the air filter. See Section 7

Check if the room door or window is open.

Keep the door and windows closed.

Check if the desired operating mode is 
selected and temperature is properly set.

Set the mode and temperature at proper set-point 
See Section 5

The exhaust hose is detached.

Make sure the exhaust hose is securely attached.

W

ater Leakage

O

verflow while moving the unit.

Empty the water tank before transport.

Check if the drain hose is kinked or bent.

Straighten the hose to avoid a trap existing.

Excessive Noise

Check if the unit is securely positioned.

P

lace the unit on horizontal and firm ground.

Check if any loose, vibrating parts.

Secure and tighten the parts.

N

oise sounds like water flowing.

N

oise comes from flowing refrigerant. This is normal.

Error
Codes

E0

C

ommunication faults between main PCB 

and display PCB.

C

heck the wire harness of the display PCB for damage.

E1

Ambient temperature sensor failure

Check connection or replace it. To clean or replace the 
temperature sensor.

E2

Coil temperature sensor failures.

Check connection or replace it. To clean or replace the 
temperature sensor.

Ft

Condensate water high level alarm.

Empty the drain pan. See Section 5.10

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

BATTERY REMOVAL

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products 

containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack 

Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

S

AC12000.V4  Issue 2 (3) 16/06/22

Summary of Contents for SAC12000.V4

Page 1: ...nt and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 1 5 Products which require more than 13 amps are supplied without a plug Contact a qualified electrician to ensure that a suitably rated supply is available Ensure that an industrial round pin plug and socket are fitted by a qualified electrician 1 1 6 If an extension cable reel is used en...

Page 2: ...evel 65dB A Power 1337W Cooling 118W Heating Rated capacity 3520W Cooling 2780W Heating Refrigerant R290 Suction side pressure 0 7MPa Supply 230V 50Hz 4 INSTALLATION IMPORTANT Allow the refrigerant to settle for at least 24 hours before using the unit 4 1 EXHAUST HOSE ASSEMBLY 4 1 1 Thread hose adaptor fig 2 onto the hose and then locate adaptor into its housing in the body 4 1 2 Pull the free end...

Page 3: ...ter one hour the set temperature is increased by 1o C After two hours the set temperature will again be increased by 1o C 5 6 3 When sleep is selected during heat mode after one hour the set temperature is decreased by 1o C After two hours the set temperature will again be decreased by 1o C 5 6 4 After two hours of auto adjustment the set temperature will be kept constant for 10 hours indicators w...

Page 4: ...pply before cleaning or performing maintenance 7 1 1 Inspect the unit on a regular basis and replace or repair any damaged parts Use recommended parts and an authorised service agent Unauthorised parts may be dangerous and will invalidate the warranty 8 DO NOT use any solvents or abrasive material to clean the plastic exterior of the unit Use only a damp soft cloth for cleaning and dry the unit af...

Page 5: ...pan See Section 5 10 Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment...