2.  INTRODUCTION & SPECIFICATION

3. PREPARATION

3.1.

 

Remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged, contact  

 

your supplier.

3.2.

 

If wheels and/or feet are not fitted to compressor, fit them using the appropriate nuts, bolts and washers supplied.

3.3.

 

Confirm that the mains voltage corresponds with the voltage shown on the compressor data plate. 

4. OPERATION 

  

WARNING!

 Ensure that you have read, understood and apply Section 1 safety instructions. 

4.1.

 

The compressor should be located and operated in a position that allows good air circulation around the unit. locate the compressor   

 

in a convenient position for the work to be undertaken. Ensure that it is standing on a stable and level surface. Ensure the feet/wheels  

 

are in direct contact with the surface. 

4.2.

 

Attach the required air tool to the air outlet. (fig1.B)

4.3.

 

Plug the mains plug into a mains electrical socket, but do not switch the compressor on until the workpiece and air tool are fully  

 

 prepared. 

4.4.

 

Switch on the unit by pulling the red on/off switch outwards(fig 1.A). 

4.5.

 

The output pressure is regulated by the pressure regulator. (fig 1.C). Turn the regulator knob clockwise to increase pressure to  

 

 

the required level and vice-versa.The setting can then be retained by tightening the red locking ring below the knob. 

 

 

 

When the compressor is not being used, set the regulated pressure to zero so as to avoid damaging the regulator.

4.5.1.  The right-hand pressure gauge (fig 1.E) indicates the pressure inside the main tank. The left-hand gauge (fig.1.D) indicates the  

 

 

pressure supplied to the air equipment. The pressure switch stops the motor when the maximum tank pressure is reached and 

 

restarts it when pressure falls below the minimum threshold - approximately 2bar (29psi) less than the maximum pressure.

Aluminium cylinder with cast iron lining gives reduced weight and improved resistance to wear. Suitable for general purpose workshop 

applications. Oil free, single piston pump is belt driven by a 1.5hp motor and fixed to a vertical type tank, saving space around the workshop. 

Precision welded receiver tank manufactured to meet Pressure Vessel Directive 2009/105/EC. Fitted with fully automatic pressure cut-out switch 

and air regulator with gauge. Supplied with handle and wheels (SAC03050 & SA03290) for easy manoeuvrability. Fitted with ASTA/BS approved 

non-rewirable plug.

 

Model No:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAC03224

. . . . . . . . . . . . .

SAC03250  . . . . . . . . . . . . . . . . . . . .SAC03290  

 

motor output:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5hp  . . . . . . . . . . . . . . . . .1.5hp  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5hp

 Voltage/Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 1ph . . . . . . . . . . . . .230V - 1ph  . . . . . . . . . . . . . . . . . . . . . 230V-1ph  

 

Rated Supply:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13A. . . . . . . . . . . . . . . . . . .13A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13A  

 

Air Displacement cfm(ltr/min): . . . . . . . . . . . . . . . . . . 5.6(158) . . . . . . . . . . . . . . .5.6(158)  . . . . . . . . . . . . . . . . . . . . . . . . 5.6(158)

 

maxiimum Free Air Delivery cfm(ltr/min) . . . . . . . . . . 3.32(94) . . . . . . . . . . . . . . .3.32(94)  . . . . . . . . . . . . . . . . . . . . . . . . 3.32(94)

 

maximum Pressure:  . . . . . . . . . . . . . . . . . . . . . . . . . 116psi/8bar  . . . . . . . . . . . .116psi/8bar. . . . . . . . . . . . . . . . . . . 116psi/bbar

 

Receiver Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . 24ltr  . . . . . . . . . . . . . . . . . .50ltr  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90ltr  

 

Dimensions (W x D x H)  . . . . . . . . . . . . . . . . . . . . . . 415 x 415 x 500mm . . . . . .430 x 455 x 710mm  . . . . .430 x 455 x 1035mm 

 

 Weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.8kg  . . . . . . . . . . . . . . . .23.4kg  . . . . . . . . . . . . . . . . . . . . . . . . . . . .35kg

SAC03224

SAC03250

SAC03290

fig.1

fig.1

fig.2

fig.3

SAC03224

SAC03250,SAC03290

noTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible 

for their safety. Children should be supervised to ensure that they do not play with the appliance.