5.  MAINTENANCE

Risk of Hand Arm Vibration Injury

Air Angle Orbital Polisher. Model No: SA722.V2

 when operated in accordance with these instructions and 

tested in accordance with BS EN 28662-1:1993, ISO 8662-1:1988 and BS EN ISO 28927-3:2009  results in the 

following vibration emission declared in accordance with BS EN 12096:1996. 

Measured vibration emission value: 

7.19m/s² 

Uncertainty:

 2.88m/s²

These values are suitable for comparison with emission levels of other tools that have been subject to the 

same test.

This tool may cause hand-arm vibration syndrome if its use is inadequately managed.

Recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 

118

 minutes in any 8 hour period.

This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.

WARNING!

 

Disconnect polisher from air supply before changing accessories, servicing or performing  

 

maintenance.

 

Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be  

 

dangerous and  will invalidate the warranty.

5.1.

  If the air supply does not have an oiler lubricate the air polisher daily with a few drops of good grade air  

 

tool oil such as Sealey ATO/500 or ATO/1000, dripped into the air inlet before use.

5.2.

   Clean the polisher after use and change pads when required. 

5.3.

   Loss of power or erratic action may be due to the following: 

 

a)

  Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose 

 

 

connectors. To remedy check the air supply and follow instructions in Section 3. 

 

b)

  Grit or gum deposits in the polisher may also reduce performance. If your model has an air strainer 

 

 

(located in the area of the air inlet), remove the strainer and clean it. Flush the polisher out with gum 

 

 

solvent oil or an equal mixture of SAE No 10 oil and kerosene. Allow to dry before use. 

 

If problems continue, contact your local Sealey service agent. 

5.4.

  For a full service contact your local Sealey service agent. 

5.5.

  When not in use, disconnect from air supply, clean polisher and store in a safe, dry, childproof location.