WARNING!

 Disconnect die grinder from air supply before changing accessories, servicing

or performing maintenance. replace or repair damaged parts. 

Use genuine parts only.

Unauthorised parts may be dangerous and will invalidate the warranty.

5.1  if the air supply does not have an oiler lubricate the air die grinder daily with a few drops of 

Sealey air die grinder oil dripped into the air inlet to prolong its life. 

5.2   Clean the die grinder after use. 

5.3   Loss of power or erratic action may be due to the following: 

a) Excessive drain on the air line. Moisture or restriction in the air pipe. incorrect size or

type of hose connectors. To remedy check the air supply and follow instructions in

chapter 3.

b) Grit or gum deposits in the die grinder may also reduce performance. if your model has

an air strainer (located in the area of the air inlet), remove the strainer and clean it.

Flush the die grinder out with gum solvent oil or an equal mixture of SAE No 10 oil and 

paraffin. Allow to dry before use.

5.4  For a full service contact your local Sealey service agent. 
5.5  When not in use, disconnect from air supply, clean die grinder and store in a safe, dry, 

childproof location.

4.  OPERATING INSTRUCTIONS

5. MAINTENANCE

6.  PARTS LISTS

4.1 

OPERATING

WARNING!

 Ensure you have read, understood and apply safety instructions.

4.1.1  Connect the die grinder to the air supply.

4.1.2  To start, hold firmly and push the trigger locking lever forward whilst depressing trigger.

4.1.3  The bit must be running at its maximum speed before attempting to grind the workpiece.

4.1.4  Slowly and smoothly bring the grinding stone toward the workpiece (avoid jerky 

 movements). 

Exert adequate pressure on the die grinder to grind according to the type and size of the 

material you are working with. Avoid subjecting stone to excessive strain or harsh impacts. 

Always hold die grinder firmly and ease grinding stone against workpiece. Maintain a 

controlled adequate progression.

4.2 

CHANGING GRINDING STONES

WARNING!

 Disconnect from the air supply before changing grinding stone.

4.2.1  Check that grinding stones are not damaged in any way such as cracks, deformations 

or splinters etc. Damaged stones must not be used.

4.2.2  Use wrenches provided to loosen collet locking collar. insert grinding bit and re-lock collar.

 

DO NOT allow die grinder to free run for an extended period of time as this will shorten its life.

SA67.V3 GRINDING STONES:

SA67WO1  MOUNTED WHEEL (10mm x 25mm)

SA67WO2  MOUNTED WHEEL (20mm x 20mm)

SA67WO3  MOUNTED WHEEL (25mm x 22mm)

SA67WO4  MOUNTED WHEEL (25mm x 10mm)

SA67WO5  MOUNTED WHEEL (20mm x 26mm)

SA67WO6  MOUNTED WHEEL (20mm x 25mm)

SA67WO7  MOUNTED WHEEL (25mm x 25mm)

SA67WO8  MOUNTED WHEEL (16mm x 26mm)

SA67WO9  MOUNTED WHEEL (25mm x 25mm)

SA67WO10 MOUNTED WHEEL (25mm x 25mm)