Sealey SA401.V2 Instructions Download Page 3

 

WARNING!

 

Disconnect gun from air supply before performing maintenance.

5.1

   Lubricate the air tool daily with a good grade of air tool oil such as Sealey ATO/500 or 

 

ATO/1000. If the compressed air system has no oiler, a few drops of oil can be poured into  

 

the air inlet of the gun each day.

5.2

  When not in use, disconnect from air supply, clean and store in a safe, dry, childproof  

 

location. 

Note!

 Faults in the compressed air system may cause loss of power or erratic action. Reduced  

 

compressor output, excessive drain on the air line, moisture or restrictions in air pipes or the  

 

use of hose connectors of incorrect size may reduce the air supply. 

 

Grit or gum deposits in the tool will reduce power and may be removed by flushing out the  

 

gun with gum solvent oil or an equal mixture of SAE10 oil and kerosene.

Note! 

If the SA401.V2 is used with cartridges for a long period, it is possible that the rubber  

 

plunger may become damaged. If it is then used with manual or bulk filling systems, the  

 

plunger may allow grease to seep from the bottom of the grease tube. To prevent this  

 

happening, check the condition of the rubber plunger, and if worn, replace before using a  

 

different fill method.

5.  MAINTENANCE

6. TROUbLESHOOTING

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA401.V2    Issue: 1 - 13/02/12

4.4.3  Operate the filler pump to fill the grease tube.

4.4.4  Disconnect the grease gun from the filler pump.

4.4.5  Press the catch plate and release the plunger rod. Push down on the plunger handle.

4.5  Operation

4.5.1  To operate the grease gun simply push the grease outlet onto the the grease nipple and  

 

operate the trigger until the desired amount of grease has been dispensed.

4.5.2  If you encounter air pockets during operation simply exert force on the plunger, press the air  

 

vent valve (fig.3) and operate trigger in short, sharp bursts until grease begins to flow from  

 

the nozzle.

Fault

Possible Cause

Corrective Action

Loss  of  power  or  erratic 

action.

Grit  or  gum  deposits  in  grease                        

gun air motor.

Air pressure too low.

Flush  out  grease  gun  air  motor 

with a suitable oil.

Check compressed air system for 

faults.

Grease gun fails to 

dispense grease.

Grease tube is empty.

Loss of prime.

Check grease tube and refill.

Repeat priming operation.

Grease  gun  continues  to 

lose prime.

Air  pockets  in  grease  tube  after 

bulk filling.

Plunger binding in grease tube.

Empty grease tube, refill and 

repeat priming operation.

Check plunger for free movement.