background image

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this equipment

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor,

Sealey Group,

Bury St. Edmunds, Suffolk.

Declaration of Conformity  

We, the sole UK importer, declare that the product listed below is in conformity with the following

standards and directives.

The construction file for this product is held by the manufacturer

and may be inspected, by a national authority, upon request

to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole UK importer of Sealey Power Products.

DIRECT DRIVE COMPRESSOR

Model: SA2225/1.5.V2

87/404/EEC Pressure Vessel Directive

89/336/EEC EMC Directive

73/23/EEC LV Directive

98/37/EC Machinery Directive

Signed by Mark Sweetman

1st February 2005

SA2225/1.5.V2  - 1 - 010205

5.6. 

Scheduled maintenance table

5.7.

Recommended oils

Recommended oil for compressors, suitable for room 

temperatures ranging from +5

O

C to +25

O

C.

SEALEY CPO or equivalent SAE 40 compressor oil.

Room temperature below +5

O

C: SAE 20 compressor oil.

Approximate oil capacity: 0.25 litres.

fig. 5

6. TROUBLESHOOTING  

7. DECLARATION OF CONFORMITY

•

•

Internal & external

inspection of tank

•

General cleaning of

compressor

Check tube fittings and

electrical connections

•

•

Check for oil leaks

Replace air filter

•

Clean intake filter

•

•

•

Check oil level

•

Drain condensation

500 hrs.

200 hrs.

100 hrs.

Daily

Maintenance

Operations

Replace oil

Check cut-out

Fault

Cause

Remedy

Pressure drop in the tank

Air leaks at connections

Run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. Tighten connections showing leaks. 

If problem persists contact Authorised ServiceAgent.

Pressure switch valve leaks when compressor is idle

Non-return valve seal defective

Empty the air tank, remove the non-return valve cap

‘E’ (fig.5) and clean, or if necessary replace, 

the seal ‘D’. 

Compressor stops and does not restart

Motor failure

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Pressure switch fault

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Filter clogged

Head gasket or valve fault

Replace filter element.

Contact Authorised Service Agent.

Compressor noisy with metallic knock

Bearing or piston damage

Contact Authorised Service Agent.

01284 757500

[email protected]

www.sealey.co.uk

01284 703534

e-mail

Web

Summary of Contents for SA2225/1.5.V2

Page 1: ...ard We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical...

Page 2: ...raying 6 0 bar is recommended pressure setting for air tools 2 2 Weight Dimensions Model Weight kg Dimensions Length x Width x Height mm SA2225 1 5 V2 28 645 x 350 x 590 Free Air Delivery cfm Model Motor Output hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level Pressure Power dB A SA2225 1 5 V2 1 5 ...

Page 3: ...mpressor air in Air out is always less than air in due to losses within the compressor and so it is important that before choosing equipment you study the Free Air Delivery figures shown in the Specification Chart Section 2 p p WARNING Ensure that you have read understand and apply Section 1 Safety Instructions 4 1 Make sure that the main switch fig 4 1 is Off down 4 2 Plug the mains cable into ma...

Page 4: ...g from 5O C to 25O C SEALEY CPO or equivalent SAE 40 compressor oil Room temperature below 5O C SAE 20 compressor oil Approximate oil capacity 0 25 litres fig 5 6 TROUBLESHOOTING 7 DECLARATION OF CONFORMITY Internal external inspection of tank General cleaning of compressor Check tube fittings and electrical connections Check for oil leaks Replace air filter Clean intake filter Check oil level Dra...