NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this equipment
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION:
For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
Declaration of Conformity
We, the sole UK importer, declare that the product listed below is in conformity with the following
standards and directives.
The construction file for this product is held by the manufacturer
and may be inspected, by a national authority, upon request
to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole UK importer of Sealey Power Products.
DIRECT DRIVE COMPRESSOR
Model: SA2225/1.5.V2
87/404/EEC Pressure Vessel Directive
89/336/EEC EMC Directive
73/23/EEC LV Directive
98/37/EC Machinery Directive
Signed by Mark Sweetman
1st February 2005
SA2225/1.5.V2 - 1 - 010205
5.6.
Scheduled maintenance table
5.7.
Recommended oils
Recommended oil for compressors, suitable for room
temperatures ranging from +5
O
C to +25
O
C.
SEALEY CPO or equivalent SAE 40 compressor oil.
Room temperature below +5
O
C: SAE 20 compressor oil.
Approximate oil capacity: 0.25 litres.
fig. 5
6. TROUBLESHOOTING
7. DECLARATION OF CONFORMITY
Internal & external
inspection of tank
General cleaning of
compressor
Check tube fittings and
electrical connections
Check for oil leaks
Replace air filter
Clean intake filter
Check oil level
Drain condensation
500 hrs.
200 hrs.
100 hrs.
Daily
Maintenance
Operations
Replace oil
Check cut-out
Fault
Cause
Remedy
Pressure drop in the tank
Air leaks at connections
Run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. Tighten connections showing leaks.
If problem persists contact Authorised ServiceAgent.
Pressure switch valve leaks when compressor is idle
Non-return valve seal defective
Empty the air tank, remove the non-return valve cap
E (fig.5) and clean, or if necessary replace,
the seal D.
Compressor stops and does not restart
Motor failure
Contact Authorised Service Agent.
Compressor does not stop at max. pressure
Pressure switch fault
Contact Authorised Service Agent.
Compressor does not stop at max. pressure
Filter clogged
Head gasket or valve fault
Replace filter element.
Contact Authorised Service Agent.
Compressor noisy with metallic knock
Bearing or piston damage
Contact Authorised Service Agent.