background image

4.  content & inStallation

4.1.    

confirm that all items are present and undamaged. if any parts are missing or damaged please contact the supplier.

 

   sA206 - combined filter, regulator with gauge, lubricator and mounting bracket.

 

   sA206fr - combined filter, regulator with gauge and mounting bracket.

 

   sA206f - filter.

 

   sA206l - lubricator.

 

   sA206r - regulator with gauge and mounting bracket.

 

   sA206fAd - filter with Auto drain, 

 

   sA206frAd -  combined filter with auto drain, regulator 

 

   with gauge and mounting bracket.

  
4.2.    

fig.1 shows a typical air line installation. the filter is located   

 

  

upstream of the regulator - unless combined, as in sA206   

 

  

and sA206fr - and the lubricator downstream.

4.3.    

filter/regulator - install using the mounting bracket provided.   

 

  

Before connecting system piping ensure that gauge is visible,   

  

unused gauge port is sealed with plug provided and that flow     

  

direction arrow matches system air flow.

 

 filter and lubricator - install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that  

  

flow arrows are correct and that filter is upstream, and lubricator downstream, of regulator.

 

 note: to ensure air-tight joints, use Ptfe tape.

5.  operation

5.1.    

regulator - the output pressure is controlled by the knob. Before pressurising the air system for the first time, pull out and rotate   

        the knob anticlockwise to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set   
        required output pressure, as shown on gauge. When the required pressure is achieved push in knob to prevent inadvertent 

 

adjustment.

 

   note: for correct pressure setting always adjust up from a lower pressure. therefore to reset from 90 to 70psi for example, reduce   

  

pressure from 90 to 60psi and then increase to 70psi.

5.2.    

filter - the bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of           

       the bowl, allow to drain and then release. drain valve has female 1/8” BsP outlet. (sA206frAd and sA206fAd have Auto drain

  

feature. When pressure in bowl drops, float valve opens and drains condensation. drain valve has male 1/8” BsP outlet).

5.3.    

lubricator - remove the filler plug (fig.2.A) and fill bowl up to max. level, with air tool oil. this can be done with the air line pressurised.  

 

With air flowing through the lubricator the oil delivery rate can be adjusted by screw (fig.2.c) whilst watching the drip rate   

 

 

through the sight dome (fig.2.B). the oil delivery rate will automatically increase or decrease in line with the air flow.

5.4.    

Both the filter and the lubricator are supplied with a metal bowl guard. to remove the guard, pull down the latch (fig.3.d) and rotate   

 

the guard until either of the two pairs of lines (fig.3.e) on the guard align with the similar marks (fig.3.f) on the head. the guard can   

 

now be removed.

 

 to refit, slide the top of the guard into the head with the guard and head markings aligned, and the rotate the guard so that the latch  

  

aligns with the marks on the head. the latch will lock into place.

 regulator - Sa206r

 

max. inlet pressure  . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

 max. outlet pressure  . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .210cfm

  Ports-inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
 outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
 

Gauge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

 

 filter - Sa206f, Sa206faD

 

max. inlet pressure  . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

 max. outlet pressure  . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .140cfm

 filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron 
  Ports-inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
 outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP

Auto drain  . . . . . . . . . . . . . . . . . . . . . . . . . . . . sA206fAd only

 

  Warning! filter and lubricator bowls are manufactured   

  from polycarbonate and must not be used at temperatures  
  over 125°f (52°c) or for pressures over 218psi (15 bar).
 polycarbonate can be damaged and may fail if exposed to  
  certain solvents either internally or externally - strong   
  alkalies, compressor oils containing aromatic  hydrocarbons  
  or fire retardant oils, or the fumes of any of these. clean   
  with warm water only.

 filter/regulator - Sa206fr, Sa206fraD

 

max. inlet pressure  . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)

 max. outlet pressure  . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)

 

max. flow rate @ 100psi (6.9 bar)  . . . . . . . . . . . . . . . .140cfm

 filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
  Ports-inlet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
 outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP
 

Gauge  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP

Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . sA206frAd only

   fig.1

   fig.2

   fig.3

sA206/206fr/206f/206l/206r/206fAd/206frAd | issue 4 04/05/17

Original Language Version

© Jack sealey limited

Reviews: