2.  IntRoDuctIon & specIFIcAtIon

Kit comprises sa0615 6ltr compressor, 5mtr air hose and nail/staple gun. compressor is also suitable for use with the sealey range of tyre 

inflators and air brushes. compressor fitted with twin gauges displaying tank and working pressures. features four anti-vibration rubber feet for 

added stability when in use. 

3.  compRessoR pRepARAtIon 

  

WARnIng! the compressor is supplied with synthetic lubricating oil in the pump - see para. 5.4.

3.1.

 

remove compressor from packaging and inspect for any shortages or damage. If there are any problems contact your supplier.

3.2.

 

confirm that the mains voltage corresponds with the voltage shown on the compressor data plate.

3.3

the compressor should be installed on a flat surface, or one that does not exceed 10

°

 either transversely or longitudinally, and should  

 

be in a position that allows good air circulation around the unit with at least 100cm between it and any other objects.

3.4. 

ImpoRtAnt! Remove the oil dipstick from the pump (fig.2), wipe it clean, re-insert it and then remove it and check that the    

 

oil level is correct (fig.3). Add oil if required until the level is correct. Replace the dipstick. 

 

Do not Attempt to Run the compRessoR untIl thIs hAs Been checkeD.

3.5. 

take care when selecting tools for use with the compressor. Air tool manufacturers normally express the volume of air  

 

 

required to operate a tool in cubic feet per minute (cfm). this refers to free air delivered by the compressor (‘air out’) which   

 

varies according to the pressure setting. Do not confuse this with the compressor displacement which is the air taken in by  

 

the compressor (‘air in’). ‘Air out’ is always less than ‘air in’ - due to losses within the compressor - so it is important that    

 

before choosing equipment, the correct Air Displacement figures are adhered to.  

 

7

 

Do not

 operate the compressor if you are tired or under the influence of alcohol, drugs or intoxicating medication.

Do not

 use this compressor to perform a task for which it is not designed.

Do not

 deface the certification plate attached to the compressor tank. 

  

DANGER! DO NOT direct the output jet of air towards people or animals.

Do not

 operate the compressor without an air filter.

Do not

 allow anyone to operate the compressor unless they have received full instruction.

 

 

WARnIng! The air tank is a pressure vessel and the following safety measures apply:

DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.

DO NOT subject the tank to impact, vibration or to heat and DO NOT allow contact with abrasive or corrosive materials.

DO drain condensation from tank daily and inspect inside walls for corrosion every three months. Have a detailed tank    

 

inspection carried out annually. The tank shell must not fall below the certified thickness at any point.

  

WARnIng! If an electrical fuse blows, ensure that it is replaced with one of identical type and rating. 

 

When not in use, disconnect from the mains, vent the tank and store the compressor in a safe, dry, childproof location.

 

When the compressor is not in use, it should be switched off, disconnected from the mains supply and the air drained from  

 

the tank. 

compressor 

motor output:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5hp

Voltage/phase:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V/1ph

current:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8a

Air displacement:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8cfm

max. free air delivery:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4cfm

tank capacity:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6ltr

max pressure:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116psi/8bar

noise level:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95dB.a

nail/staple gun

maximum pressure:

 . . . . . . . . . . . . . . . . . . . . . . . . .120psi/8.3bar

operating pressure:

 . . . . . . . . . . . . . . . . . . . 70-110psi/4.8-7.6bar  

Weight:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2kg

staple capacity:

 . . . . . . . . . . . . . . . . . . . . . . . . . 16-40mm 18sWG

nail capacity:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-50mm 18sWG

4.  compRessoR opeRAtIon  

  

WARnIng! ensuRe thAt You hAVe ReAD, unDeRstooD AnD 

 

ApplIeD sectIon 1 sAFetY InstRuctIons.

note:  DutY cYcle:

 this is a 70% duty cycle air compressor. do not run the 

 

air compressor for more than approximately 40 minutes in any one hour.

 

doing so could damage the compressor.

4.1.

 

make sure that the main switch (fig.1.1) is ‘off’ (pushed down).

4.2.

 

check the oil level by checking the dipstick (figs.2 and 3).

4.3.

 

ensure that the tank drain valve is closed (fig.5).

4.4.

 

ensure that the outlet pressure regulator is not at full pressure (fully 

 

clockwise), if it is, turn the knob anti-clockwise a few turns (fig.1.2).

4.5.

 

connect the required air tool to the compressor via an air line connected

 

to the air outlet (fig.1.4).

4.6.

 

Plug the mains cable into the mains supply and start the compressor by

 

pulling up the main switch into the 'on' position (fig.1.1).

4.7.

 

allow the pressure in the tank to rise to the maximum at which point the

 

compressor will automatically cut out. tank pressure is shown on the

 

larger gauge (fig.1.6).

4.8.

 

Begin to gradually increase the pressure regulator by turning the knob

 

clockwise until the small gauge registers the required operating 

 

pressure specified for the tool connected. always 

adjust up

 to the 

 

required pressure rather than down from a higher pressure. the required

 

setting, once achieved, can be locked by screwing the locking ring (fig.1.3) up tight underneath the adjusting knob.

4.9.

 

commence using the air tool. the compressor will operate automatically, cutting in and out as required to restore the air pressure    

 

in the tank. the pressure switch (fig.1.8) stops the motor when the maximum tank pressure is reached and restarts it when pressure   

 

falls below the minimum threshold - approximately 2 bar (29psi) less than the maximum pressure.

fig.1

Original Language Version

 sa0615KIt      Issue: 2- 20/02/12

Summary of Contents for SA0615KIT

Page 1: ...check that there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated above DO NOT connect either wire to the earth terminal 1 1...

Page 2: ...brasive or corrosive materials 3 DO drain condensation from tank daily and inspect inside walls for corrosion every three months Have a detailed tank inspection carried out annually The tank shell must not fall below the certified thickness at any point WARNING If an electrical fuse blows ensure that it is replaced with one of identical type and rating 3 When not in use disconnect from the mains v...

Page 3: ...sation Wear ear and eye protection Open the tank drain valve fig 5 slowly allowing air and moisture to bleed from the tank After bleeding close the drain valve to prevent debris building up in the valve WARNING Water that is allowed to remain in the tank during storage will corrode and weaken the air tank which could cause the tank to rupture To avoid serious injury drain the tank after each use o...

Page 4: ...k Bearing or piston damage Contact Authorised Service Agent 8 Excessive moisture in discharged air High humidity environment Drain tank after each use 5 4 to be carried out after every 100 hours of use a Check that the automatic cut out at maximum pressure and the automatic cut in at 2bar below that are operating correctly b Replace the lubricating oil For oil specifications see below Remove the o...

Page 5: ...o high an air pressure and unclean air will shorten the product life due to excessive wear and may be dangerous causing damage and or personal injury 8 1 4 Drain the air tank daily Water in the air line will damage the nail staple gun and will invalidate your warranty 8 1 5 Clean the air inlet filter weekly Recommended hook up is shown in fig 7 8 1 6 Line pressure should be increased to compensate...

Page 6: ...rect size or type of hose connectors To remedy check the air supply and follow the instructions in section 8 b Grit or gum deposits in the nail staple gun may also reduce performance Flush the nail staple gun out with gum solvent oil or an equal mixture of SAE No 10 oil and kerosene Allow to dry before use If continuing to experience problems contact your local Sealey service agent 10 4 Check movi...

Page 7: ...ed Trigger valve head is damaged Trigger valve stem or seal damaged Check and replace 2 Air leak near bottom of tool Loose screws Worn or damaged O rings or bumper Tighten screws Check and replace O rings or bumper 3 Air leak between body and cylinder cap Loose screws Worn or damaged O rings or seals Tighten screws Check and replace O rings or seal 4 Blade driving fastener too deep Worn or damaged...