  2.   SPECiFiCATiOn & FEATURES

2.1  Specification

 

Models .............................RS1.V4 ......RS102.V3

 

cold cranking amps .............300A ..............600A

 

Peak Amps .........................1000A ............1600A

 

Voltage ....................................12V ................24V

 

Auxiliary output ......................12V ................12V

 

cable and clamp Length ..0.5mtr. ............1.0mtr

 

Weight ................................. 8.2kg ................ 9kg

 

Models .........................RS103.V2 ......RS104.V2 ....... RS105.V2

 

cold cranking amps ...........1000A ..............500A ...... 1000/500A

 

Peak Amps .........................3200A ............1600A .... 3200/1600A

 

Voltage ....................................12V ................24V ............ 12/24V

 

Auxiliary output ......................12V ................12V ................. 12V

 

cable and clamp Length ..1.8mtr. ...........1.8mtr. ............ 1.8mtr.

 

Weight ............................... 16.9kg ........... 17.2kg .............17.5kg

2.2  Product Features 

 

(Key to figs. 1,2 & 3 )

 

1) PosItIVE BAttErY cLAMP

 

2) fLEXIBLE HEAVY DutY coPPEr cABLE 

 

3) cHArGInG PoInt

 

4) 12VDc outPut/cHArGInG socKEt

 

5) tEst Button

 

6) AMBEr LED cHArGInG InDIcAtor

 

7) rED PoWEr LEVEL LED InDIcAtors

 

8) GrEEn fuLLY cHArGED LED InDIcAtor

 

9) fLEXIBLE HEAVY DutY coPPEr cABLE 

 

10) nEGAtIVE BAttErY cLAMP

 

11) sAfEtY storAGE HoLstEr

 

12) HEAVY DutY PLAstIc cAsE

 

13) sAfEtY storAGE HoLstEr

 

14) 12VoLt sYstEM rEcHArGE InDIcAtor

 

15) 24VoLt sYstEM rEcHArGE InDIcAtor

 

16) 3 PosItIon sELEctor sWItcH 12V/off/24V

RS1.V4

RS102.V3

RS103.V2

RS104.V2

RS105.V2

fig.3

fig.2

fig.1

Original Language Version

rs1.V4, rs102.V3, rs103.V2, rs104.V2, rs105.V2    Issue: 3 - 04/11/09

1.3  ELECTRiCAL SAFETY (with respect to mains chargers)

  

WARninG!

 It is the user’s responsibility to check the following:

 

You must check the Ac adaptor to ensure that it is safe before  

 

using. 

You must 

inspect the power supply lead, plugs and all 

 

electrical connections for wear and damage.  

 

You must

 ensure the risk of electric shock is minimised by the  

 

installation of appropriate safety devices. An rccB (residual  

 

current circuit Breaker) should be incorporated in the main  

 

distribution board. We recommend that an rcD (residual  

 

current Device) is used with all electrical products.  

 

It is particularly important to use an rcD with portable products  

 

that plug into an electrical supply not protected by an rccB. If  

 

in doubt consult a qualified electrician. You can obtain a  

 

residual current Device through your sealey dealer.  

 

You must 

read and understand instructions concerning  

 

electrical safety.

1.3.1 the

 Electricity At Work Act 1989

 requires all portable 

 

electrical appliances, if used on business premises, to be tested  

 

by a qualified  person, using a Portable Appliance tester (PAt),  

 

at least once a year.

1.3.2 the 

Health & Safety at Work Act 1974

 makes owners of 

 

electrical appliances responsible for the safe condition of the  

 

appliance and the safety of the appliance operator. If in any  

 

doubt about electrical safety, contact a qualified electrician.

1.3.3 

DO

 ensure that the insulation on all cables and the product itself  

 

is safe before connecting to the mains power supply. 

1.3.4 

DO

 ensure that cables are always protected against short circuit  

 

and overload.

1.3.5 

DO

 regularly inspect power supply, leads, plugs for wear and  

 

damage and power connections to ensure that none is loose.

1.3.6 

DO

 check product voltage is the same as power supply to be  

 

used and check that all fused plugs are fitted with the correct  

 

capacity fuses.