5.1. 

The inverter monitors the following potentially hazardous conditions:

 

5.1.1.  Low Battery Voltage - This condition is not harmful to the inverter but could damage the power source. The inverter   

 

automatically shuts down when input voltage drops to 10.5V. When the condition is corrected, the unit may be restarted. 

5.1.2.  Short Circuit - Reverse polarity or short circuit of the load will usually result in the opening of the short circuit protection and  

 

blowing the fuse(s). As the fuses are internal we recommend contacting your local repair agent or Sealeys technical  

 

help line directly on 01284 757505 for guidance. 

5.1.3.  High Temperature - When the temperature of the internal heat sink reaches 65°C, the solid state temperature sensor will  

 

automatically shut the unit down. Once it is allowed to cool, the unit may be restarted.

Environmental Protection. 

  

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and  packaging should be  

 

  sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.

  

 

  When the product is no longer required, it must be disposed of in an environmentally protective way. 

4.1. 

Wattage Loading. 

4.1.1.  Inductive loads, such as TV’s and stereos, require more current to operate than do resistive loads of the same wattage  

 

rating. Induction motors, as well as some televisions, may require 2 to 6 times their wattage rating to start up. The most  

 

demanding in this category are those that start under load, such as compressors and pumps. Testing is the only   

 

definitive way to determine whether a specific load can be started and how long it can run. The unit will simply shut  

 

down if it is overloaded. To restart the unit after a shutdown due to overloading, remove the overload.             

 

 

The inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, microwave  

 

ovens and toasters.

4.2.   Battery Operating Time.

 

4.2.1.  The battery operating time will vary depending on battery capacity and the current draw frrom the inverter. 

 

It is recommended that the operator start the engine every 15 minutes to recharge the battery. This will prevent any  

 

unexpected shutdown of the equipment and will ensure that there is always sufficient battery capacity to start the  

 

vehicle.The inverter may be used either with the engine running or turned off. However, the inverter must be switched OFF when  

 

starting the vehicle.

4.2.2.  The inverter draws less than 1.0 Ampere from the battery when it is not supplying power to a load (see section 2 for exact  

 

figure). In most cases, the inverter may be left connected to the battery when it is not in use. If the vehicle will not be used  

 

for several days, disconnect the unit from the battery.

 

 Problem

Possible Cause

Suggested Remedy

 

Unit will not operate

1. Poor DC contact

2. Battery voltage below 10.5V.

3. Load draws too much power.

4. Inverter in thermal shutdown.

5. Vehicle battery in poor condition.

6. Fuses blown due to short circuit.

1. Check all DC contacts.

2. Recharge or replace battery. 

3. Reduce load.

4. Allow inverter to cool.

5. Check / replace battery. 

6.  Contact  local  repair  agent  or  Sealey  technical  help             

    line for guidance.

Low output voltage.

Check with voltmeter.

Use true RMS voltmeter.

Overload LED illuminates.  

Unit overloaded.

Switch off and reduce load.

Television Interference

Inverter too close to the television.

 Locate the inverter as far as possible from the TV,  

 antenna and other cables.

  4.   OPERATING TIPS

  5.   PROTECTIVE FEATURES

 6. 

  TROUBLE SHOOTING

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, 

email [email protected] or phone 01284 757500.

©  Jack Sealey Ltd

Reviews: