AK2018 - 3 - 220206
INSTRUCTIONS FOR:
3 IN 1 METAL, VOLTAGE AND STUD DETECTOR
Model:
AK2018
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
Combined unit for the accurate detection of live or dead electricity cables, water or gas pipes and wooden
studs or battens. Powered by a 9V battery (not supplied) the detector will, with red and green LED displays
and an audible signal, show the presence of metal, electricity and studs or battens.
1.
DESCRIPTION
2.
SAFETY
!
When the unit gives a ‘no voltage’ reading (no flashing of red LED and beeping of the buzzer when
touching the conductor), check the unit on a known voltage source BEFORE touching the conductor.
!
Intended for indoor use only -
DO NOT
get the detector wet.
!
The unit will not detect electricity in shielded conductors i.e. those in a metal conduit. In such
cases it will indicate only the presence of metal.
3.
OPERATION
!
Warning! Ensure that you read, understand and apply the safety instructions before attempting to use the
detector.
Note:
Remove the battery cover. Install a 9V PP9 battery. Refit the battery cover. Refer to Fig. 2.
3.1
Metal Detection
3.1.1 Rotate the blue knob (Voltage/Metal Detector) fully downwards and move the selector switch to the Voltage/Metal Detection
position. The green LED will illuminate. Make sure that the unit is well away from any metal or current carrying conductor
and hold it as shown in Fig. 3.
3.1.2 Turn
the
blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blue
knob slowly until the indicators just go off . The unit is now ready for use.
3.1.3 Hold
the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. The red LED and a continuous
buzzer tone will come on when a metal object is in the vicinity.
3.1.4 If
the indicators do not come on, or will not go off, after the unit has been switched on, the detector requires adjustment.
For adjustment details, please refer to Section 3.5.
3.2
Voltage Detection
3.2.1
Turn the blue knob (Voltage/Metal Detector) downwards and move the selector switch to the (Voltage/Metal Detector)
position. The green LED will illuminate immediately. Make sure that the unit is well away from any metal or current carrying
conductor.
3.2.2 Turn
the
blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blue
knob slowly until the indicators just go off . The unit is now ready for use.
3.2.3
Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. Current-carrying conductors will be
shown by a flashing red LED and the sound of an interrupting buzzer.
3.2.4
If the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.
For adjustment details, please refer to Section 3.5.
Fig. 2
Fig. 3
Fig. 4
AK2018 - 3 - 220206
INSTRUCTIONS FOR:
3 IN 1 METAL, VOLTAGE AND STUD DETECTOR
Model:
AK2018
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
Combined unit for the accurate detection of live or dead electricity cables, water or gas pipes and wooden
studs or battens. Powered by a 9V battery (not supplied) the detector will, with red and green LED displays
and an audible signal, show the presence of metal, electricity and studs or battens.
1.
DESCRIPTION
2.
SAFETY
!
When the unit gives a ‘no voltage’ reading (no flashing of red LED and beeping of the buzzer when
touching the conductor), check the unit on a known voltage source BEFORE touching the conductor.
!
Intended for indoor use only -
DO NOT
get the detector wet.
!
The unit will not detect electricity in shielded conductors i.e. those in a metal conduit. In such
cases it will indicate only the presence of metal.
3.
OPERATION
!
Warning! Ensure that you read, understand and apply the safety instructions before attempting to use the
detector.
Note:
Remove the battery cover. Install a 9V PP9 battery. Refit the battery cover. Refer to Fig. 2.
3.1
Metal Detection
3.1.1 Rotate the blue knob (Voltage/Metal Detector) fully downwards and move the selector switch to the Voltage/Metal Detection
position. The green LED will illuminate. Make sure that the unit is well away from any metal or current carrying conductor
and hold it as shown in Fig. 3.
3.1.2 Turn
the
blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blue
knob slowly until the indicators just go off. The unit is now ready for use.
3.1.3 Hold
the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. The red LED and a continuous
buzzer tone will come on when a metal object is in the vicinity.
3.1.4 If
the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.
For adjustment details, refer to Section 3.5.
3.2
Voltage Detection
3.2.1
Turn the blue knob (Voltage/Metal Detector) downwards and move the selector switch to the Voltage/Metal Detector
position. The green LED will illuminate immediately. Make sure that the unit is well away from any metal or current carrying
conductor.
3.2.2 Turn
the
blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blue
knob slowly until the indicators just go off . The unit is now ready for use.
3.2.3
Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. Current-carrying conductors will be
shown by a flashing red LED and the sound of an interrupting buzzer.
3.2.4
If the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.
For adjustment details, refer to Section 3.5.
Fig. 2
Fig. 3
Fig. 4
Fig. 1
Fig. 1