3.  SPECIFICATION

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PPF20

  . . . . . . . . . . . . . . . . . . . . .

PPF30

Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20tonne

  . . . . . . . . . . . . . . . . . . . .

30tonne 

Ram Stroke: . . . . . . . . . . . . . . . . . . . . . . . . . .

195mm

  . . . . . . . . . . . . . . . . . . . . .

195mm

Ram Diameter: . . . . . . . . . . . . . . . . . . . . . . . . .

51mm

  . . . . . . . . . . . . . . . . . . . . . .

58mm

Maximum Height - Ram to Table:

. . . . . . . . . .

858mm

  . . . . . . . . . . . . . . . . . . . . .

854mm

Minimum Height - Ram to Table:

  . . . . . . . . . . .

21mm

  . . . . . . . . . . . . . . . . . . . . . .

17mm

Table Aperture: . . . . . . . . . . . . . . . . . . . . . . . .

148mm

  . . . . . . . . . . . . . . . . . . . . .

148mm

Working Table Depth: . . . . . . . . . . . . . . . . . . .

172mm

  . . . . . . . . . . . . . . . . . . . . .

172mm

Working Table Width: . . . . . . . . . . . . . . . . . . .

670mm

  . . . . . . . . . . . . . . . . . . . . .

670mm

Overall Height:

  . . . . . . . . . . . . . . . . . . . . . . .

1850mm

  . . . . . . . . . . . . . . . . . . . .

1850mm

Gauge Included:

. . . . . . . . . . . . . . . . . . . . . . . . . . .Yes  . . . . . . . . . . . . . . . . . . . . . . . . Yes

4.  ASSEMBLY

‰

‰

‰‰

WARNING! 

these presses are heavy, the use of a lifting appliance is recommended.

4.1.    

FITTING THE FEET

4.1.1.   

Attach the permanent press feet (figs.1 & 2).

4.1.2.   

It is recommended that, for safest operation, the press is secured to the floor using 

 

 

the fixing holes in the feet.

4.2.    

FITTING THE PUMP HANDLES

4.2.1. 

  

The press is supplied with the pump handles disconnected, to save damage in  

 

transit (fig.3).

4.2.2.   

Cut the plastic ties to release the pump handles (fig.4).

4.2.3.   

Fix pump handle by means of screw, guide bush and nut (fig.5).

4.2.4.   

Fit the long pump handle into the socket of high speed pump (fig.6).

5.  OPERATION

5.1.     BLEEDING THE HYDRAULIC CIRCUIT

5.1.1.    Before first use, any air trapped in the hydraulic circuit will need to be bled.

5.1.2.    To do this: open the release valve and pump both pumps 10 times.

5.1.3.    Close the release valve and pump a further 10 times. The ram should    

 extend.

5.1.4. 

   Open the release valve again; the ram should retract.

5.1.5.    If the hydraulic circuit still appears sluggish, repeat the process.

5.2.     USING THE PRESS

5.2.1.    Insert the saddle into the ram head and secure with the grub screw (fig.7).

5.2.2. 

   Lift or lower the table to the required height and insert the pins to support it.

5.2.3. 

   Place the arbor plate on the press bed frame, then place workpiece onto the  

  arbor plate and align beneath the ram as required. 

 NOTE:

 care must be taken to ensure an arbor does not fall from the press  

 

work table. If necessary, fix in position.

5.2.4. 

   Close the release valve by turning it clockwise fully.

5.2.5. 

   Pump with the high speed pump until the saddle is close to the workpiece.

5.2.6. 

   Use the low speed pump to perform the pressing operation, monitoring the  

  pressure via the pressure gauge. Using this pump allows greater control and  

 feel.

5.2.7. 

   When the operation is finished, release the pressure gradually by opening  

  the release valve slowly.

5.2.8. 

   When the ram has retracted fully, remove the work from the table.

5.2.9. 

   When the press is not in use, ensure that the ram is retracted fully to help    

  avoid corrosion.

P

PF20 / PPF30 | Issue 2 (H,F,S,3) 07/06/19

Original Language Version

© Jack Sealey Limited

fig.1

fig.2

fig.3

fig.4

fig.5

fig.6

fig.7

Reviews: