2.1. 

ELECTRICAL SAFETY

   

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and  

 

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

 

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We    

 

also recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that  

 

are plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a  

 

 

Residual Current Device by contacting your Sealey dealer. 

 

You must also read and understand the following instructions concerning electrical safety.

2.1.1. 

The Electricity at Work Act 1989

 requires that all portable electrical appliances, if used on business premises, are tested by a  

 

 

qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

2.1.2. 

The Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those  

 

 

appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

2.1.3. 

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 2.1.1. and 2.1.2.  

 

and use a Portable Appliance Tester.

2.1.4. 

Ensure that cables are always protected against short circuit and overload.

2.1.5. 

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.

2.1.6. 

Important: 

Ensure that the voltage marked on the appliance matches the power supply to be  

 

used and that the plug is fitted with the correct fuse - see rating at right.

2.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

2.1.8. 

DO NO

T pull the plug from the socket by the cable.

2.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Have any faulty item repaired  

 

or replaced by a qualified electrician. 

2.1.10.  This product will require more than a 13Amp electrical supply, so a plug is not fitted, it is a  

 

single phase machine and must be run from a minimum 16Amp supply. To achieve maximum output this model will require a 30Amp  

 

fused supply. We recommend you discuss the installation of an industrial round pin plug and socket with a qualified electrician.

 

Fit a plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation  

 

 

    extends beyond the cable restraint and that the restraint is tight.  

 

Double insulated products, which are always marked with this symbol 

    ,

 are fitted with live (brown) and neutral (blue) wires only.  

 

To rewire, connect the wires as indicated above. 

DO NOT

 connect either wire to the earth terminal.

  

WARNING!

 Reminder, the electrical installation of the plasma cutting unit must only be carried out by a qualified electrician. 

  

WARNING!

 Be very cautious if using a generator to power the inverter. The generator must be self regulating and stable with regard  

 

to voltage, waveform and frequency. The output must be greater than the power consumption of the inverter. If any of these  

 

requirements is not met the electronics within the inverter may be affected.

NOTE:   The use of an unregulated generator may be dangerous and will invalidate the warranty.

   

WARNING!

 The inverter may produce voltage surges in the mains supply which can damage other sensitive equipment  

 

(e.g. computers). It is recommended that the inverter is connected to a power supply that does not feed any sensitive equipment.

2.1.11.  If an extension reel is used it should be as short as possible and fully unwound before connection. A reel with an RCD fitted is  

 

 

preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least 1.5mm²,    

 

but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output  

 

sockets, we recommend the use of 2.5mm² section cable.

INSTRUCTIONS FOR:

PLASMA INVERTER

MODEL No:

 

PP35PLUS

Thank you for purchasing a Sealey plasma inverter. Manufactured to a high standard this product will, if used according to these instructions and properly

maintained, give you years of trouble free performance.

IMPORTANT

BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS 

AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL NJURY 

AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

  2.  SAFETY INSTRUCTIONS

1.1. 

Introduction

 

Weighing only 16.8kg but with the power to cut up to 10mm steel, this machine features an integral compressor. Inverter power  

 

 

supply fitted with plasma cutter control circuitry. Inverter features four-LED information panel including torch under-voltage, air fault,  

 

general fault (thermostat, over/under-voltage, over-current) and power on. Supplied with plasma torch and earth cable. Uses air to   

 

strike arc making it suitable for use near electrical equipment. Ideal for cutting steel, stainless, galvanized steel, aluminium, copper   

 

and brass. Includes integral air compressor, air filter and regulator unit with panel-mounted pressure gauge. IP23 Rated.

Model No:  . . . . . . . . . . . . . . . . . . . . . PP35PLUS

Power Output . . . . . . . . . . . . . . . . . . . . . . . .7-40A

Duty Cycle  . . . . . . . . . . . . . . . . . . . . .30% @ 35A

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60% @ 24A

Air Flow  . . . . . . . . . . . . . . . . . . . . Integral Comp.

Air Pressure . . . . . . . . . . . . . . . . . Integral Comp.

Supply Voltage . . . . . . . . . . . . . . . . . . 230V - 1ph

Power Absorbed . . . . . . . . . . . . . . . . . . . . . 4.5kW

Insulation Class  . . . . . . . . . . . . . . . . . . . . . . . . . H

Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP23

Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.8kg

Max. Cutting Capacity (Carbon Steel) . . . .  10mm

Replacement Consumables  . . . .Part No. . Qty.

Electrode, Short Low Power. . 120/802420. . . . 5 

Electrode, Long  . . . . . . . . . . . 120/802428. . . . 5

Nozzle, Short Low Power. . . . 120/802423. . . . 5

Nozzle, Long  . . . . . . . . . . . . . 120/802429. . . . 5

Diffuser . . . . . . . . . . . . . . . . . . 120/802422. . . . 5

Safety Cap . . . . . . . . . . . . . . . 120/802425. . . . 2

  1.  INTRODUCTION & SPECIFICATIONS

Original Language Version

PP35PLUS    Issue: 2 - 15/05/12

230V 1ph

THE PLASMA CUTTER 

MUST BE CONNECTED TO A 

30 AMP SUPPLY FOR  

MAXIMUM OUTPUT

1.2.          Specification

Summary of Contents for PP35PLUS

Page 1: ...INSTRUCTIONS FOR PLASMA INVERTER PP35PLUS MODEL No Original Language Version PP35PLUS Issue 2 15 05 12 ...

Page 2: ... neutral blue wires only To rewire connect the wires as indicated above DO NOT connect either wire to the earth terminal WARNING Reminder the electrical installation of the plasma cutting unit must only be carried out by a qualified electrician WARNING Be very cautious if using a generator to power the inverter The generator must be self regulating and stable with regard to voltage waveform and fr...

Page 3: ...move all flammable materials such as waste rags etc DO NOT cut containers or pipes which have held flammable materials gases liquids or solids DO NOT cut materials that have been cleaned with chlorinated solvents or near such solvents as vapours from the arc action may produce toxic gases DO NOT operate the inverter while under the influence of drugs alcohol or intoxicating medication or if tired ...

Page 4: ...nimise the possibility of accidental starting the button must be pressed for at least 2 10ths of a second before the cutting operation will start fig 1 fig 2 WARNING Before operating the machine ensure that you read understand and apply Section 2 safety instructions and that you have familiarised yourself with the controls Ensure that the machine is disconnected from the power supply before moving...

Page 5: ...giving the following data 1 The standard relating to the safety and construction of welding and cutting equipment 2 Symbol referring to the internal structure of the machine 3 Symbol referring to the plasma cutting procedure 4 S Indicates that cutting may be carried out in environments with a heightened risk of electric shock e g very close to large metallic objects 5 Power Supply AC number of pha...

Page 6: ...duit or equivalent This shielding should be connected to the power source so that good electrical contact is maintained between the conduit and the welding power source enclosure 9 6 Maintenance of the equipment The equipment should be routinely maintained according to these instructions All access and service covers should be closed and properly fastened when the welding equipment is in operation...

Reviews: