3.1. 

Air Supply

 

3.1.1.  Clean the air inlet filter weekly. Recommended hook-up is shown in fig.1.

3.1.2.  Ensure the tyre buffer air valve (trigger) is in the "off" position before connecting to the air  

 

supply.

3.1.3.  An air pressure of 90psi is required and an air flow according to specification.

3.1.4. 

 

WARNING! 

Ensure that the air supply is clean and does not exceed 90psi whilst  

 

operating the tyre buffer. Too high an air pressure and unclean air will shorten the   

 

product’s life due to excessive wear, and may be dangerous causing damage and/or  

 

personal injury. 

3.1.5.  Drain the air tank daily. Water in the air line will damage the tyre buffer. 

3.1.6.  Line pressure should be increased to compensate for unusually long air hoses (over 8 

 

metres). The minimum hose diameter should be ¼” I.D. and fittings must have the same 

 

inside dimensions. 

3.1.7.  Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain 

 

that all connections are secure. 

3.2. 

Couplings. 

 

Vibration may cause failure if a quick change coupling is connected directly to the tyre  

 

buffer. To overcome this, connect a leader hose to the buffer. A quick change coupling  

 

may then be used to connect the leader hose to the air line recoil hose (see figs.1 & 2). 

3. 

PREPARATION

4.    OPERATION

 

WARNING! Ensure that the safety instructions are read, understood and applied  

 

before use.

4.1.

 

Only use tyre buffing cones that are specifically designed for use with this tyre buffer.

 

Tyre buffing cone: Part No. SA651/C is available from your Sealey Dealer.

4.2.

 

To fit the adaptor, push forward the locking collet on the chuck and push the adaptor into  

 

the chuck. Release the locking collet, and check to make sure that the adaptor is locked  

 

in position.

4.3.

 

Thread the buffing tool bit onto the adaptor and use two spanners to lock it in place.

4.4.

 

Connect the tyre buffer to the air hose as in chapter 3.

4.5.

 

To start, hold the tyre buffer firmly and push the trigger locking lever forward whilst  

 

depressing  the trigger. The tyre buffer must be running at its maximum speed and then  

 

slowly and smoothly bring the tyre buffer towards the workpiece. Exert adequate pressure  

 

on the tyre buffer as required. Avoid subjecting the tyre buffer to excessive strain or harsh  

 

impacts. Hold tyre buffer firmly and maintain a controlled adequate progression. 

DO NOT

  

 

use any additional force upon the tyre buffer.

4.6.

 

The flow of air may be regulated by turning the screw on the underside of the tyre buffer.

 

Adjust the exhaust outlet as required, to direct the air flow away from the operator’s hands. 

 

DO NOT

 allow the tyre buffer to free run for an extended period of time as this will shorten  

 

its life.

fig.1

fig.2

Original Language Version

SA651.V3    Issue: 1 - 20/10/11