3.    ASSEMBLY INSTRUCTIONS

Remove parts from packing and take items out of the tank. Before assembly check parts to ensure
they are complete and not damaged.
3.1.    Close lid (4) of tank (1), and turn unit upside down. 

Rest tank on a clean soft surface (i.e. 

cardboard) ensuring lid is secured in the closed position.

3.2.    Attach the four legs (21) to the tank brackets with the pan head screws, spring washers and 

hex nuts (22, 23, 24) 

but do not tighten

3.3.

Place the lower shelf (20) between the four legs (21) with flat surface facing downward and 
fix with washers, hex nuts and screws (22, 23, 24). 

3.4.

With the legs pressed tightly against the lower shelf, tighten all the screws commencing with 
those attaching the shelf.

3.5.

Hold the lid closed and stand the assembled unit upright. Open the lid 

but do not extend the 

lid too far.

3.6.

Place the tank work shelf (42) on the two welded supports located inside the tank.

3.7.

Remove the self tapping screws from the cover plate of the pump unit (A) and check to 
see if there is any supporting packing inside. If so, remove the supporting packing and 
replace the cover.

3.8.

Place the pump into the tank unit and pass the switch unit through the slot in the cleaning 
tank side (A). As the unit protrudes through the slot secure it by placing the underside lip 
over the edge of the tank. Attach the flexible pipe (27) to pump (A).

3.9

To fit turbo valve assembly unscrew flexible tube (E), nut (D) and one nylon washer (C).

3.10. Insert threaded end of turbo valve (B) through hole in side of tank and retain with washer 

(C) and nut (D). Refit the flexible tube (E). Check that turbo valve (B) is closed.

4.  OPERATING INSTRUCTIONS

!

WARNING! Wear safety clothing, eye protection and gloves and ensure you read, under-

stand and apply the safety instructions in Section 1.

4.1.

Ensure the tank is located on a firm level surface in a well ventilated area and is switched 
off  and unplugged from the mains power supply.

4.2.

Fill the tank with Sealey solvent - approx. 50 litres. Minimum level 

must

cover pump inlet - 

approx. 40 litres. Follow the solvent instructions on the packaging.

4.3.

Plug the pump into the power supply and switch on. The cleaning agent will flow through 
the flexible tube. 

4.4. Place 

parts 

to be washed into the basket, or directly into the tank. Direct solvent flow onto 

parts. Heavily soiled items may be left to soak before cleaning.

4.5.

To improve cleaning and reduce pre-soak time turn on turbo valve to provide an agitating air
flow into the cleaning fluid.

4.6.

Do not leave the unit operating unattended. Check the fluid level does not fall below the 
pump inlet. 

4.7. 

When cleaning is complete remove all parts whilst ensuring the minimum of cleaning agent 
spillage.

4.8.

Switch off the pump, close the lid and disconnect from the mains power supply.  
Clean up any spillage.

4.9.

Dispose of waste liquids in accordance with local authority regulations.

IMPORTANT! 

The SM20 has an anti-fire device built into the unit. In the event of a fire the lid will

automatically close. 

DO NOT prop the lid open as this will prevent the automatic safety

feature from operating.

Once actuated, the fire detection device cannot be re-used and must

be replaced before further use. 

#

When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position 
that would prevent the lid from closing fully if and when the fusible link activates.

5.  MAINTENANCE

5. 1.

Clean the inside of the tank at regular intervals and keep the main body of the unit clean.

5. 2.

Regularly wash the pump filter in clean degreaser and replace if necessary.

5. 3.

Ensure that all screws and bolts are kept tight. 

Declaration of Conformity 

We, the sole importer into the UK, declare that the product listed here is

in conformity with the following standards and directives.

The construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to
contacting Jack Sealey Ltd.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.

Turbo Parts Cleaning Tank

Model: SM20.V3

73/23/EEC Low Voltage Directive

89/336/EEC EMC Directive

98/37/EC Machinery Directive

93/68/EEC CE Marking Directive

2002/95/EC RoHS Directive

2002/96/EC WEEE Directive

Signed by Mark Sweetman

1st June 2007

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this equipment.

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

SM20.V3 - 1 - 110607

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk