background image

  6.  DrY VACUUM ClEANING

 

WArNING!

 ensure you read, understand and apply section 1 'safety Instructions'. 

 reminder: 

DO NOt

 vacuum hazardous substances. use of an incorrect filter will invalidate your warranty.

6.1.

  ensure the machine is unplugged from the power supply.

6.2.

  For dry vacuuming fit the polyester ring filter item "B" over the filter cage shown in 6.3. 

6.4.

  replace the top section onto the tank together with the filter, and clip in place.

6.5.

  Insert the larger end of the flexible hose into the front inlet on the tank fully and an "engagement click" will be heard. 

6.6.

  Push the required attachment onto the free end of the hose.   

6.7.

  ensure the switch is 'off' ("o") before plugging into the power supply.

6.8.

  switch the motor/motors on to vacuum, position "I".

6.9. 

When vacuuming is completed, push the "o" button/buttons to switch the vacuum off, then unplug from the power supply. 

  8.  WEt VACUUM ClEANING

 

WArNING! Ensure you read, understand and apply Section 1 ‘Safety Instructions’. Reminder: Remove plug from power supply  

 

before opening unit. DO NOT vacuum solvents, explosives, inflammable and/or hazardous liquids such as petrol, oil, spirits,    

 

paint, thinners, acids etc.  Use of an incorrect filter will invalidate your warranty.

8.1.

  make sure the tank is clean and free from dust and dirt. 

8.2.

  ensure the machine is unplugged from the power supply. 

8.3.

  For wet vacuum cleaning the foam filter ("A") must be used. remove filter cage (7.4), remove any paper filter

 

fitted. ensure the foam filter is clean and dry. Place the foam filter ("A") over the exposed neck and adjust carefully.

8.4.

  re-position the head onto the tank, and clip into place.

8.5.

  Insert the larger end of the flexible hose into the front inlet on the tank fully and an engagement "click" will be heard. 

8.6.

  Fit the required accessories or tubes to the suction hose. 

8.7.

  ensure the switch is 'off' ("o") before plugging into the power supply. 

8.8.

  switch the motor/motors on to vacuum, position "I".

8.9.

  When vacuuming is completed, push the "o" button/buttons to switch the vacuum off, then unplug from the power

 supply. 

8.10.

  After use, empty the tank via the drain hose, and tip any remaining. re-clip the hose and dry the tank with a cloth.

 

WArNING! the tank is not designed for liquid storage. Always empty liquids fully after use. 

 

Never store the cleaner with liquid in the tank 

 Pc85    Issue: 1 - 01/12/14

Original Language Version

 © Jack sealey limited

6.2

6.3

6.6

6.8

6.1

6.7

6.5

6.9

6.4

  7.  FINE DUSt VACUUMING

 

WArNING!

 ensure you read, understand and apply section 1 'safety Instructions'. 

 reminder: 

DO NOt

 vacuum hazardous substances. use of an incorrect filter will invalidate your warranty.

7.1.

  ensure the machine is unplugged from the power supply.

7.2.

  For fine dust dry vacuuming fit the dust collection bag filter item "c". 

7.3.

  the opening in the bag has a flexible rubber neck which will shroud the internal nozzle, terminating in a recessed annular ring. 

7.4.

  remove the filter cage by slackening the three screws in the keyhole slots and twist cage. replace the top section onto the tank, and    

 

clip in place.

7.5.

  Insert the larger end of the flexible hose into the front inlet on the tank fully and an "engagement click" will be heard. 

7.6.

  Push the required attachment onto the free end of the hose.   

7.7.

  ensure the switch is 'off' ("o") before plugging into the power supply.

7.8.

  switch the motor/motors on to vacuum, position "I".

7.9. 

When vacuuming is completed, push the "o" button/buttons to switch the vacuum off, then unplug from the power supply. 

7.2

7.3

7.6

7.8

7.1

7.7

7.5

7.9

7.4

drain hose clip 

3-screws

hose

release

button

6.3

Filter cage

Summary of Contents for PC85

Page 1: ...in plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N d After wiring check that there are no bare wires that all wires have been corre...

Page 2: ...mper power cable winder and accessories holder Model is also a powerful liquid vacuum cleaner and is fitted with a gravity feed drainage pipe Supplied with a full Ø45mm accessory kit 3 specification Model No PC85 Motor Power 2400W Supply 230V Drum Size 75ltr Airflow 340mtr hr Weight 22 2kg Accessories and optional filters fig 4 A Sponge Foam Filter PC85 SF B Polyester Ring Filter PC85 PF C Fine Pa...

Page 3: ... inlet on the tank fully and an engagement click will be heard 8 6 Fit the required accessories or tubes to the suction hose 8 7 Ensure the switch is Off O before plugging into the power supply 8 8 Switch the motor motors on to vacuum position I 8 9 When vacuuming is completed push the O button buttons to switch the vacuum off then unplug from the power supply 8 10 After use empty the tank via the...

Page 4: ...t and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information PC85 Issue 1 01 12 14 Origin...

Reviews: